Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractEffect of oak wood barrel capacity and utilization time on phenolic and sensorial profile evolution of an Encruzado white wine    Next AbstractNanomaterial Gas Sensors for Online Monitoring System of Fruit Jams »

Biosensors (Basel)


Title:Innovative Sensor Approach to Follow Campylobacter jejuni Development
Author(s):Nunez-Carmona E; Abbatangelo M; Sberveglieri V;
Address:"Department of Information Engineering, University of Brescia, Brescia, via Branze, 38, 25123 Brescia, BS, Italy. e.nunezcarmona@unibs.it. Department of Information Engineering, University of Brescia, Brescia, via Branze, 38, 25123 Brescia, BS, Italy. m.abbatangelo@unibs.it. CNR-IBBR, Institute of Bioscience and Bioresources, via Madonna del Piano, 10, 50019 Sesto Fiorentino, FI, Italy. veronica.sberveglieri@ibbr.cnr.it. NANO SENSOR SYSTEMS, NASYS Spin-Off University of Brescia, Brescia, via Camillo Brozzoni, 9, 25125 Brescia, BS, Italy. veronica.sberveglieri@ibbr.cnr.it"
Journal Title:Biosensors (Basel)
Year:2019
Volume:20190107
Issue:1
Page Number: -
DOI: 10.3390/bios9010008
ISSN/ISBN:2079-6374 (Electronic) 2079-6374 (Linking)
Abstract:"Campylobacter spp infection affects more than 200,000 people every year in Europe and in the last four years a trend shows an increase in campylobacteriosis. The main vehicle for transmission of the bacterium is contaminated food like meat, milk, fruit and vegetables. In this study, the aim was to find characteristic volatile organic compounds (VOCs) of C. jejuni in order to detect its presence with an array of metal oxide (MOX) gas sensors. Using a starting concentration of 10(3) CFU/mL, VOCs were analyzed using Gas-Chromatography Mass-Spectrometry (GC-MS) with a Solid-Phase Micro Extraction (SPME) technique at the initial time (T0) and after 20 h (T20). It has been found that a Campylobacter sample at T20 is characterized by a higher number of alcohol compounds that the one at T0 and this is due to sugar fermentation. Sensor results showed the ability of the system to follow bacteria curve growth from T0 to T20 using Principal Component Analysis (PCA). In particular, this results in a decrease of DeltaR/R(0) value over time. For this reason, MOX sensors are a promising technology for the development of a rapid and sensitive system for C. jejuni"
Keywords:Animals Campylobacter jejuni/*chemistry/isolation & purification/metabolism *Gas Chromatography-Mass Spectrometry Gases/chemistry Limit of Detection Meat/microbiology Metals/chemistry Milk/microbiology Nanowires/chemistry Oxides/chemistry Principal Compon;
Notes:"MedlineNunez-Carmona, Estefania Abbatangelo, Marco Sberveglieri, Veronica eng Switzerland 2019/01/10 Biosensors (Basel). 2019 Jan 7; 9(1):8. doi: 10.3390/bios9010008"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024