Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"VOC- and SVOC-emissions from adhesives, floor coverings and complete floor structures"    Next Abstract"PepO, a CovRS-controlled endopeptidase, disrupts Streptococcus pyogenes quorum sensing" »

Indoor Air


Title:Volatile organic compounds from building products-Results from six round robin tests with emission test chambers conducted between 2008 and 2018
Author(s):Wilke O; Horn W; Richter M; Jann O;
Address:"Bundesanstalt fur Materialforschung und -prufung (BAM), Berlin, Germany"
Journal Title:Indoor Air
Year:2021
Volume:20210503
Issue:6
Page Number:2049 - 2057
DOI: 10.1111/ina.12848
ISSN/ISBN:1600-0668 (Electronic) 0905-6947 (Linking)
Abstract:"Emission testing of volatile organic compounds (VOC) from materials and products is commonly based on emission test chamber measurements. To ensure the comparability of results from different testing laboratories, their measurement performance must be verified. For this purpose, Bundesanstalt fur Materialforschung und -prufung (BAM) organizes an international proficiency test (round robin test, RRT) every two years using well-characterized test materials (one sealant, one furniture board, and four times a lacquer) with defined VOC emissions. The materials fulfilled the requirements of homogeneity, reproducibility, and stability. Altogether, 36 VOCs were included of which 33 gave test chamber air concentrations between 13 and 83 microg/m(3) . This is the typical concentration range to be expected and to be quantified when performing chamber tests. Three compounds had higher concentrations between 326 and 1105 microg/m(3) . In this paper, the relative standard deviations (RSD) of BAM round robin tests since 2008 are compared and the improvement of the comparability of the emission chamber testing is shown by the decrease of the mean RSD down to 28% in 2018. In contrast, the first large European interlaboratory comparison in 1999 showed a mean RSD of 51%"
Keywords:"*Air Pollution, Indoor/analysis Construction Materials Environmental Monitoring Reproducibility of Results *Volatile Organic Compounds/analysis VOC emission construction product emission test chamber interlaboratory comparison proficiency testing round ro;"
Notes:"MedlineWilke, Olaf Horn, Wolfgang Richter, Matthias Jann, Oliver eng Research Support, Non-U.S. Gov't England 2021/05/05 Indoor Air. 2021 Nov; 31(6):2049-2057. doi: 10.1111/ina.12848. Epub 2021 May 3"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024