Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractOzone Formation Induced by the Impact of Reactive Bromine and Iodine Species on Photochemistry in a Polluted Marine Environment    Next AbstractSelection on Coding and Regulatory Variation Maintains Individuality in Major Urinary Protein Scent Marks in Wild Mice »

Environ Sci Technol


Title:Time-weighted average SPME analysis for in planta determination of cVOCs
Author(s):Sheehan EM; Limmer MA; Mayer P; Karlson UG; Burken JG;
Address:"Department of Civil, Architectural and Environmental Engineering, Missouri University of Science and Technology, Rolla, Missouri, United States"
Journal Title:Environ Sci Technol
Year:2012
Volume:20120301
Issue:6
Page Number:3319 - 3325
DOI: 10.1021/es2041898
ISSN/ISBN:1520-5851 (Electronic) 0013-936X (Linking)
Abstract:"The potential of phytoscreening for plume delineation at contaminated sites has promoted interest in innovative, sensitive contaminant sampling techniques. Solid-phase microextraction (SPME) methods have been developed, offering quick, undemanding, noninvasive sampling without the use of solvents. In this study, time-weighted average SPME (TWA-SPME) sampling was evaluated for in planta quantification of chlorinated solvents. TWA-SPME was found to have increased sensitivity over headspace and equilibrium SPME sampling. Using a variety of chlorinated solvents and a polydimethylsiloxane/carboxen (PDMS/CAR) SPME fiber, most compounds exhibited near linear or linear uptake over the sampling period. Smaller, less hydrophobic compounds exhibited more nonlinearity than larger, more hydrophobic molecules. Using a specifically designed in planta sampler, field sampling was conducted at a site contaminated with chlorinated solvents. Sampling with TWA-SPME produced instrument responses ranging from 5 to over 200 times higher than headspace tree core sampling. This work demonstrates that TWA-SPME can be used for in planta detection of a broad range of chlorinated solvents and methods can likely be applied to other volatile and semivolatile organic compounds"
Keywords:"Dimethylpolysiloxanes Environmental Monitoring/instrumentation/*methods Environmental Pollutants/*analysis Hydrocarbons, Chlorinated/*analysis Solid Phase Microextraction Solvents/analysis *Trees Volatile Organic Compounds/*analysis;"
Notes:"MedlineSheehan, Emily M Limmer, Matt A Mayer, Philipp Karlson, Ulrich Gosewinkel Burken, Joel G eng Research Support, Non-U.S. Gov't 2012/02/16 Environ Sci Technol. 2012 Mar 20; 46(6):3319-25. doi: 10.1021/es2041898. Epub 2012 Mar 1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024