Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSensory and instrumental volatile flavor analysis of commercial orange juices prepared by different processing methods    Next AbstractYeast as a tractable genetic system for functional studies of the insulin-degrading enzyme »

Environ Res


Title:The passive sampler assisted human exposure risk characterization for tetrachloroethene soil vapor intrusion scenario
Author(s):Kim PG; Tarafdar A; Lee KY; Kwon JH; Hong Y;
Address:"Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea. School of Biosystems and Food Engineering, University College Dublin, Belfield, Dublin 4, Ireland. R&D Center, H-Plus Eco Ltd.,130-70, Jinsangmi-ro 813beon-gil, Seolseong-myeon, Icheon-si, 17412, Republic of Korea. Department of Environmental Engineering, College of Science and Technology, Korea University Sejong Campus, Sejong City, 30019, Republic of Korea. Electronic address: yongseokhong@korea.ac.kr"
Journal Title:Environ Res
Year:2023
Volume:20230930
Issue:
Page Number:117238 -
DOI: 10.1016/j.envres.2023.117238
ISSN/ISBN:1096-0953 (Electronic) 0013-9351 (Linking)
Abstract:"The potential human health risks associated with soil vapor intrusion and volatile organic compounds (VOCs) exposure were characterized at an industrialized site by the quantification of gaseous VOCs in soil pores using a passive sampling technique. The gaseous tetrachloroethene (PCE) in soil pores varied between 12 and 5,400?ª+mug?ª+m(-3) showing 3 orders of magnitude variation with dependence on groundwater PCE concentrations. Though the PCE concentration in the air only varied between 0.45 and 1.5?ª+mug?ª+m(-3) showing negligible variations compared to the variation observed in soil pores. The PCE concentration in the air varied between 0.45 and 1.5?ª+mug?ª+m(-3). The calculation of fugacity suggested that the PCE in the test site originated from groundwater. Measured PCE in groundwater ranged from 14 to 2,400 times higher than PCE in soil gas. This indicates that conducting a vapor intrusion risk assessment using passive soil gas sampling is critical for accurate risk characterization and assessment. Estimated PCE inhalation cancer risks for street cleaners and indoor residents varied between 10(-6) and 10(-4) with a low plausible hazard, and between 10(-3) and 10(-2) with a high risk, respectively. The results of this study demonstrate that passive sampling offers a significantly lower cost and labor-intensive approach compared to traditional methods for assessing pollution distribution in contaminated sites and characterizing risks. This highlights the potential for wider application of passive sampling techniques in environmental studies"
Keywords:Fugacity Passive sampling Risk characterization VOCs Vapor intrusion Volatile organic compounds;
Notes:"PublisherKim, Pil-Gon Tarafdar, Abhrajyoti Lee, Keum Young Kwon, Jung-Hwan Hong, Yongseok eng Netherlands 2023/10/03 Environ Res. 2023 Sep 30:117238. doi: 10.1016/j.envres.2023.117238"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024