Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSynergistic Effects of SO(2) and NH(3) Coexistence on SOA Formation from Gasoline Evaporative Emissions    Next AbstractSub-second thermal desorption of a micro-sorbent trap for the analysis of ambient volatile organic compounds »

Anal Chem


Title:Synchronized discharge ionization for analysis of volatile organic compounds using a hand-held ion trap mass spectrometer
Author(s):Chen TC; Ouyang Z;
Address:"Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana 47907, United States"
Journal Title:Anal Chem
Year:2013
Volume:20130107
Issue:3
Page Number:1767 - 1772
DOI: 10.1021/ac303112d
ISSN/ISBN:1520-6882 (Electronic) 0003-2700 (Linking)
Abstract:"The sensitivity of mass analysis is highly dependent on the efficiencies of the sample introduction, analyte ionization, and subsequent ion transfer to the mass analyzer. For miniature mass spectrometry (MS) systems, it is highly desirable to maximize the amount of the samples that can be introduced at the pumping capability highly compromised and to have the MS analysis performed with simple electronics and robust in-vacuum components. In this study, a discharge ionization source synchronized with the sample introduction has been developed for hand-held mass spectrometers with discontinuous atmospheric pressure interfaces (DAPI). The flow rate of the sample introduced with a DAPI can be much higher than that allowed with a conventional continuous atmospheric pressure interface. The pressure variation associated with the DAPI operation was used to turn on and off the synchronized discharge ionization (SDI). For analysis of volatile organic compounds (VOCs) in air samples, the SDI has been shown to be soft and molecular ions of the VOCs have been observed as the major species. Since the ions could be transferred directly to the ion trap mass analyzer without a barrier for maintaining pressure differences, high sensitivity in chemical analysis was also achieved, with limits of detection (LODs) better than 1 ppbv obtained for PAHs (polycyclic aromatic hydrocarbons) in air"
Keywords:*Ion-Selective Electrodes Miniaturization/*methods Volatile Organic Compounds/*analysis/chemistry;
Notes:"MedlineChen, Tsung-Chi Ouyang, Zheng eng Research Support, U.S. Gov't, Non-P.H.S. 2012/12/22 Anal Chem. 2013 Feb 5; 85(3):1767-72. doi: 10.1021/ac303112d. Epub 2013 Jan 7"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024