« Previous AbstractThe potential of breath analysis to improve outcome for patients with lung cancer    Next Abstract"Pheromone-gland-specific fatty-acyl reductase in the adzuki bean borer, Ostrinia scapulalis (Lepidoptera: Crambidae)" »

Anal Bioanal Chem


Title:Sensitive multiresidue method by HS-SPME/GC-MS for 10 volatile organic compounds in urine matrix: a new tool for biomonitoring studies on children
Author(s):Antonucci A; Vitali M; Avino P; Manigrasso M; Protano C;
Address:"Department of Ecological and Biological Sciences, Tuscia University, Via S. Maria in Gradi, 4, 01100, Viterbo, Italy. Department of Public Health and Infectious Diseases, Sapienza University of Rome, Piazzale Aldo Moro, 5, 00185, Rome, Italy. Department of Public Health and Infectious Diseases, Sapienza University of Rome, Piazzale Aldo Moro, 5, 00185, Rome, Italy. matteo.vitali@uniroma1.it. Department of Technological Innovations, INAIL, Via IV Novembre 144, 00187, Rome, Italy"
Journal Title:Anal Bioanal Chem
Year:2016
Volume:20160616
Issue:21
Page Number:5789 - 5800
DOI: 10.1007/s00216-016-9682-x
ISSN/ISBN:1618-2650 (Electronic) 1618-2642 (Linking)
Abstract:"A HS-SPME method coupled with GC-MS analysis has been developed for simultaneously measuring the concentration of 10 volatile organic compounds (VOCs) (benzene, toluene, ethylbenzene, o-, m-, and p-xylene, methyl tert-butyl ether, ethyl tert-butyl ether, 2-methyl-2-butyl methyl ether, and diisopropyl ether) in urine matrix as a biomonitoring tool for populations at low levels of exposure to such VOCs. These compounds, potentially toxic for human health, are common contaminants of both outdoor and indoor air, as they are released by autovehicular traffic; some of them are also present in environmental tobacco smoke (ETS). Thus, the exposure to these pollutants cannot be neglected and should be assessed. The low limits of detection and quantification (LODs and LOQs <6.5 and 7.5 ng L(-1), respectively) and the high reproducibility (CVs <4 %) make the developed method suited for biomonitoring populations exposed at low levels such as children. Further, the method is cost-effective and low in time-consumption; therefore, it is useful for investigating large populations. It has been applied to children exposed to traffic pollution and/or ETS; the relevant results are reported, and the relevant implications are discussed"
Keywords:Air Pollutants/analysis/isolation & purification/*urine Child Environmental Exposure/*analysis Environmental Monitoring/methods Gas Chromatography-Mass Spectrometry/*methods Humans Limit of Detection Reproducibility of Results Solid Phase Microextraction/;
Notes:"MedlineAntonucci, Arianna Vitali, Matteo Avino, Pasquale Manigrasso, Maurizio Protano, Carmela eng Germany 2016/06/18 Anal Bioanal Chem. 2016 Aug; 408(21):5789-5800. doi: 10.1007/s00216-016-9682-x. Epub 2016 Jun 16"

 