Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDrought Impacts on Secondary Organic Aerosol: A Case Study in the Southeast United States    Next AbstractEnvironmental implications from the priority pollutants screening in impoundment reservoir along the eastern route of China's South-to-North Water Diversion Project »

Talanta


Title:"Development of microwave plasma proton transfer reaction mass spectrometry (MWP-PTR-MS) for on-line monitoring of volatile organic compounds: Design, characterization and performance evaluation"
Author(s):Zhao Z; Dai J; Wang T; Niu G; He F; Duan Y;
Address:"College of Chemical Engineering, Chengdu, 610064, PR China. College of Chemistry and Material Science, Northwest University, Xi'an, 710069, PR China. College of Life Science, Chengdu, 610064, PR China. School of Aeronautics & Astronautics, Chengdu, 610064, PR China. College of Manufacturing Science and Engineering, Sichuan University, Chengdu, 610064, PR China. Electronic address: yduan@scu.edu.cn"
Journal Title:Talanta
Year:2020
Volume:20191012
Issue:
Page Number:120468 -
DOI: 10.1016/j.talanta.2019.120468
ISSN/ISBN:1873-3573 (Electronic) 0039-9140 (Linking)
Abstract:"Proton transfer reaction mass spectrometry (PTR-MS) is a revolutionary on-line VOCs monitoring method. In this study, a new microwave plasma-based proton transfer reaction mass spectrometry (MWP-PTR-MS) is developed. The MWP consists of a surfatron type resonator and a cooperative ion extraction device to achieve high efficiency production of hydronium ions. Non-local thermodynamic equilibrium water plasma is generated in a quartz tube at 200?ª+Pa with 2.45?ª+GHz microwave. Characters of MWP, such as emission spectroscopy, input power, dirty ion suppressing and ion extraction, are explored systematically. With the same test platform, MWP has a 7-fold increment of hydronium ion production rate than glow discharge source. The counts rate of hydronium ion is 8?ª+x?ª+10(6) cps with abundance of NO(+) and O(2)(+) is less than 0.4% and 5% respectively. The performance of MWP-PTR-MS is validated by analysis of several chemicals and demonstration application is conducted. The instrument showed good linearity above 99% in the range of 4.5?ª+x?ª+10(-11) to 4.5?ª+x?ª+10(-9)?ª+mol/L. Benefited from the character of surface wave and 2.45?ª+GHz microwave, MWP has high potential in improving the performance and reliability of current PTR-MS"
Keywords:Ion source Microwave plasma Proton transfer reaction mass spectrometry Volatile organic compounds;
Notes:"PubMed-not-MEDLINEZhao, Zhongjun Dai, Jianxiong Wang, Tianzhi Niu, Guanghui He, Feiyao Duan, Yixiang eng Netherlands 2019/12/11 Talanta. 2020 Feb 1; 208:120468. doi: 10.1016/j.talanta.2019.120468. Epub 2019 Oct 12"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024