Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDo linear logistic model analyses of volatile biomarkers in exhaled breath of cystic fibrosis patients reliably indicate Pseudomonas aeruginosa infection?    Next Abstract"Gas chromatography and isotope ratio mass spectrometry of Pinot Noir wine volatile compounds (delta(13)C) and solid residues (delta(13)C, delta(15)N) for the reassessment of vineyard water-status" »

Anal Chem


Title:"Electrostatic Switching and Selection of H(3)O(+), NO(+), and O(2)(+*) Reagent Ions for Selected Ion Flow-Drift Tube Mass Spectrometric Analyses of Air and Breath"
Author(s):Spanel P; Spesyvyi A; Smith D;
Address:"J. Heyrovsky Institute of Physical Chemistry of the Czech Academy of Sciences , Dolejskova 3 , 18223 Prague 8 , Czech Republic"
Journal Title:Anal Chem
Year:2019
Volume:20190327
Issue:8
Page Number:5380 - 5388
DOI: 10.1021/acs.analchem.9b00530
ISSN/ISBN:1520-6882 (Electronic) 0003-2700 (Linking)
Abstract:"Soft chemical ionization mass spectrometry techniques, particularly the well-established proton transfer reaction mass spectrometry, PTR-MS, and selected ion flow tube mass spectrometry, SIFT-MS, are widely used for real-time quantification of volatile organic compounds in ambient air and exhaled breath with applications ranging from environmental science to medicine. The most common reagent ions H(3)O(+), NO(+), or O(2)(+*) can be selected either by quadrupole mass filtering from a discharge ion source, which is relatively inefficient, or by switching the gas/vapor in the ion source, which is relatively slow. The chosen reagent ions are introduced into a flow tube or flow-drift tube reactor where they react with analyte molecules in sample gas. This article describes a new electrostatic reagent ion switching, ERIS, technique by which H(3)O(+), NO(+), and O(2)(+*) reagent ions, produced simultaneously in three separate gas discharges, can be purified in post-discharge source drift tubes, switched rapidly, and selected for transport into a flow-drift tube reactor. The construction of the device and the ion-molecule chemistry exploited to purify the individual reagent ions are described. The speed and sensitivity of ERIS coupled to a selected ion flow-drift tube mass spectrometry, SIFDT-MS, is demonstrated by the simultaneous quantification of methanol with H(3)O(+), acetone with NO(+), and dimethyl sulfide with O(2)(+*) reagent ions in single breath exhalations. The present ERIS approach is shown to be preferable to the previously used quadrupole filtering, as it increases analytical sensitivity of the SIFDT-MS instrument while reducing its size and the required number of vacuum pumps"
Keywords:Air Body Fluids/*chemistry *Breath Tests Gases/chemistry Humans Indicators and Reagents/*analysis Ions/analysis Mass Spectrometry/instrumentation Nitric Oxide/*analysis Onium Compounds/*analysis Oxygen/*analysis Static Electricity;
Notes:"MedlineSpanel, Patrik Spesyvyi, Anatolii Smith, David eng Research Support, Non-U.S. Gov't 2019/03/15 Anal Chem. 2019 Apr 16; 91(8):5380-5388. doi: 10.1021/acs.analchem.9b00530. Epub 2019 Mar 27"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024