Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIncreased number of volatile organic compounds over malignant glottic lesions    Next AbstractJasmonate-induced nicotine formation in tobacco is mediated by tobacco COI1 and JAZ genes »

Talanta


Title:"The active and passive sampling of benzene, toluene, ethyl benzene and xylenes compounds using the inside needle capillary adsorption trap device"
Author(s):Shojania S; Oleschuk RD; McComb ME; Gesser HD; Chow A;
Address:"Department of Chemistry, University of Manitoba, Winnipeg, Manitoba R3T 2N2, Canada"
Journal Title:Talanta
Year:1999
Volume:50
Issue:1
Page Number:193 - 205
DOI: 10.1016/s0039-9140(99)00120-4
ISSN/ISBN:0039-9140 (Print) 0039-9140 (Linking)
Abstract:"A new and simple method of solventless extraction of volatile organic compounds (VOCs) from air is presented. The sampling device has an adsorbing carbon coating on the interior surface of a hollow needle, and is called the inside needle capillary adsorption trap (INCAT). This paper describes a study of the reproducibility in the preparation and sampling of the INCAT device. In addition, this paper examines the effects of sample volume in active sampling and exposure time in passive sampling on the analyte adsorption. Analysis was achieved by sampling the air from an environmental chamber doped with benzene, toluene, ethyl benzene and xylenes (BTEX) compounds. Initial rates of adsorption were found to vary among the different compounds, but ranged from 0.0099 to 0.016 nmol h(-1) for passive sampling and from 2.2 to 10 nmol h(-1) for active sampling. Analysis was done by thermal desorption of the adsorbed compounds directly into a gas chromatograph injection port. Quantification of the analysis was done by comparison to actively sampled activated carbon solid phase extraction (SPE) measurements"
Keywords:
Notes:"PubMed-not-MEDLINEShojania, S Oleschuk, R D McComb, M E Gesser, H D Chow, A eng Netherlands 2008/10/31 Talanta. 1999 Aug 23; 50(1):193-205. doi: 10.1016/s0039-9140(99)00120-4"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-12-2024