Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAdaptive management of invasive pests in natural protected areas: the case of Matsucoccus feytaudi in Central Italy    Next AbstractHermetia illucens (L.) (Diptera: Stratiomyidae) Odorant Binding Proteins and Their Interactions with Selected Volatile Organic Compounds: An In Silico Approach »

Anal Chem


Title:Increasing the isolated quantities and purities of volatile compounds by using a triple Deans-switch multidimensional preparative gas chromatographic system with an apolar-wax-ionic liquid stationary-phase combination
Author(s):Sciarrone D; Panto S; Ragonese C; Tranchida PQ; Dugo P; Mondello L;
Address:"Dipartimento Farmaco-chimico, Facolta di Farmacia, Universita di Messina, viale Annunziata, 98168 Messina, Italy"
Journal Title:Anal Chem
Year:2012
Volume:20120801
Issue:16
Page Number:7092 - 7098
DOI: 10.1021/ac3013829
ISSN/ISBN:1520-6882 (Electronic) 0003-2700 (Linking)
Abstract:"A novel preparative-scale triple gas chromatographic system, equipped with three Deans-switch devices, is herein described. The isolation of volatile compounds was achieved by using a lab-made collection system. Considerations are made on the possibility to inject high volumes of neat sample, maintaining, at the same time, high resolution levels. The degree of recovery of a series of compounds, characterized by a differing volatility, is also reported. In this respect, different collection conditions were evaluated, namely, the presence (or not) of packing material as well as CO(2) cooling, in various combinations. Finally, the interconnected features, that is time requirements and the isolation of 'acceptable' analyte quantities (e.g., milligram level for NMR characterization), are related to parameters such as analyte concentration, injected volume, collection conditions, and number of GC runs. The results herein reported will demonstrate the need for a high-resolution GC step, prior to analyte collection, in the prep-GC analysis of complex samples"
Keywords:"Chromatography, Gas/instrumentation/*methods Daucus carota/chemistry Ionic Liquids/*chemistry Oils, Volatile/analysis/isolation & purification Polyethylene Glycols/chemistry Seeds/chemistry Volatile Organic Compounds/*analysis/*isolation & purification;"
Notes:"MedlineSciarrone, Danilo Panto, Sebastiano Ragonese, Carla Tranchida, Peter Quinto Dugo, Paola Mondello, Luigi eng Research Support, Non-U.S. Gov't 2012/07/28 Anal Chem. 2012 Aug 21; 84(16):7092-8. doi: 10.1021/ac3013829. Epub 2012 Aug 1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024