Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractChemical and Thermo-Mechanical Properties of Waterborne Polyurethane Dispersion Derived from Jatropha Oil    Next Abstract"Disruption of sexual selection in sand gobies (Pomatoschistus minutus) by 17alpha-ethinyl estradiol, an endocrine disruptor" »

Sensors (Basel)


Title:Multivariate Analysis as a Tool to Identify Concentrations from Strongly Overlapping Gas Spectra
Author(s):Saalberg Y; Wolff M;
Address:"Heinrich Blasius Institute of Physical Technologies, Hamburg University of Applied Sciences, Berliner Tor 21, 20099 Hamburg, Germany. yannick.saalberg@haw-hamburg.de. School of Engineering and Computing, University of the West of Scotland, High Street, Paisley PA1 2BE, UK. yannick.saalberg@haw-hamburg.de. Heinrich Blasius Institute of Physical Technologies, Hamburg University of Applied Sciences, Berliner Tor 21, 20099 Hamburg, Germany. marcus.wolff@haw-hamburg.de"
Journal Title:Sensors (Basel)
Year:2018
Volume:20180515
Issue:5
Page Number: -
DOI: 10.3390/s18051562
ISSN/ISBN:1424-8220 (Electronic) 1424-8220 (Linking)
Abstract:"We applied a multivariate analysis (MVA) to spectroscopic data of gas mixtures in the mid-IR in order to calculate the concentrations of the single components which exhibit strongly overlapping absorption spectra. This is a common challenge in broadband spectroscopy. Photoacoustic (PA) measurements of different volatile organic compounds (VOCs) in the wavelength region of 3250 nm to 3550 nm served as the exemplary detection technique. Partial least squares regression (PLS) was used to calculate concentrations from the PA spectra. After calibration, the PLS model was able to determine concentrations of single VOCs with a relative accuracy of 2.60%"
Keywords:Opo Pas Pls Voc concentration determination multivariate analysis overlapping spectra partial least squares regression photoacoustic spectroscopy;
Notes:"PubMed-not-MEDLINESaalberg, Yannick Wolff, Marcus eng Switzerland 2018/05/16 Sensors (Basel). 2018 May 15; 18(5):1562. doi: 10.3390/s18051562"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024