Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDirect analysis of large living organism by megavolt electrostatic ionization mass spectrometry    Next AbstractContribution of first- versus second-generation products to secondary organic aerosols formed in the oxidation of biogenic hydrocarbons »

Sci Technol Built Environ


Title:Evaluating IAQ and Energy Impacts of Ventilation in a Net-Zero Energy House Using a Coupled Model
Author(s):Ng L; Poppendieck D; Dols W; Emmerich S;
Address:"Engineering Laboratory, National Institute of Standards and Technology, 100 Bureau Drive Gaithersburg, MD 20899"
Journal Title:Sci Technol Built Environ
Year:2018
Volume:24
Issue:
Page Number: -
DOI: 10.1080/23744731.2017.1401403
ISSN/ISBN:2374-4731 (Print) 2374-474X (Electronic) 2374-4731 (Linking)
Abstract:"The National Institute of Standards and Technology constructed the Net-Zero Energy (NZE) Residential Test Facility to support the development and adoption of cost-effective NZE designs and technologies. In support of indoor air quality goals, contaminant source control approaches were implemented that minimized the use of products containing urea-formaldehyde resin and utilized products with relatively low volatile organic compound emissions. Indoor and outdoor concentrations of formaldehyde and acetaldehyde were measured approximately monthly for 15 months. Independent emission measurements of formaldehyde were made in a small chamber system to determine the emission rates from samples of the wood flooring, plywood, and wood cabinetry taken from the house. Blower door tests were performed to determine the leakage area of the exterior envelope, the interior floors, and transfer grilles between floors. Real-time formaldehyde concentration and energy measurements were used to verify the indoor concentrations and energy predictions of a coupled CONTAM-EnergyPlus model of the house. The verified model was then used to evaluate the impacts of different outdoor air ventilation rates on indoor concentrations and energy. This work demonstrates the need for consideration of source control options during product selection and the provision of mechanical ventilation, especially in homes with relatively airtight envelopes"
Keywords:
Notes:"PubMed-not-MEDLINENg, Lisa Poppendieck, Dustin Dols, William Emmerich, Steven eng 9999-NIST/Intramural NIST DOC/ 2018/01/01 Sci Technol Built Environ. 2018; 24:10.1080/23744731.2017.1401403. doi: 10.1080/23744731.2017.1401403"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024