Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractOdors detected by mice deficient in cyclic nucleotide-gated channel subunit A2 stimulate the main olfactory system    Next Abstract"Identification and Knockdown of the Olfactory Receptor (OrCo) in Gypsy Moth, Lymantria dispar" »

Anal Chem


Title:Detection and quantification of trace organic contaminants in water using the FT-IR-attenuated total reflectance technique
Author(s):Lin W; Li Z;
Address:"Department of Chemistry and Biochemistry, California State University Fullerton, Fullerton, California 92834, USA"
Journal Title:Anal Chem
Year:2010
Volume:82
Issue:2
Page Number:505 - 515
DOI: 10.1021/ac901192d
ISSN/ISBN:1520-6882 (Electronic) 0003-2700 (Linking)
Abstract:"The Fourier transform infrared-attenuated total reflectance (FT-IR-ATR) technique has been used to detect and quantify the following volatile organic compounds (VOCs) in water: 1,1,1,2-tetrachloroethane, 1,1,2,2-tetrachloroethane, styrene, and tetrachloroethylene, among which the first three compounds were investigated at parts per million levels for the first time. Enhancement of the detection was made by (1) coating the ATR crystal with a hydrophobic polymer membrane, (2) optimizing the flow rate of the sample solution, (3) varying polymer membrane thickness, and (4) increasing the number of reflection bounces within the ATR crystal. Our flow rate optimization confirmed a previous finding that turbulent flow is more favorable than laminar flow in detecting the VOCs in water. However, decreases of ATR signal intensity were observed at very high turbulency due to analytes flowing too quickly through and exiting the ATR cell to be adsorbed onto the polymer membrane. The optimal membrane thickness was found to be associated with the maximum overlap between the IR evanescent wave penetration depth and the analyte diffusion depth. Consequently, there is no universal optimal flow rate and optimal polymer membrane thickness for detection of all VOCs. Doubling the number of IR reflection bounces within the ATR crystal enhanced both detection and sensitivity by about a factor of 2. Finally, it was observed that the detection limit concentrations decrease with the water solubility of the VOCs"
Keywords:"Ethane/analogs & derivatives/analysis Hydrocarbons, Chlorinated/analysis Polymers/chemistry Spectroscopy, Fourier Transform Infrared/*methods Styrene/analysis Tetrachloroethylene/analysis Volatile Organic Compounds/*analysis/chemistry Water/*chemistry Wat;"
Notes:"MedlineLin, Wendy Li, Zhuangjie eng Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S. 2009/12/30 Anal Chem. 2010 Jan 15; 82(2):505-15. doi: 10.1021/ac901192d"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024