Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAmine Modification of Silica Aerogels/Xerogels for Removal of Relevant Environmental Pollutants    Next AbstractCombination of highly efficient microflora to degrade paint spray exhaust gas »

Anal Chem


Title:Fully Automated Online Dynamic In-Tube Extraction for Continuous Sampling of Volatile Organic Compounds in Air
Author(s):Lan H; Holopainen J; Hartonen K; Jussila M; Ritala M; Riekkola ML;
Address:"Department of Chemistry , University of Helsinki , P.O. Box 55, 00014 Helsinki , Finland. Institute for Atmospheric and Earth System Research , University of Helsinki , P.O. Box 64, 00014 Helsinki , Finland"
Journal Title:Anal Chem
Year:2019
Volume:20190619
Issue:13
Page Number:8507 - 8515
DOI: 10.1021/acs.analchem.9b01668
ISSN/ISBN:1520-6882 (Electronic) 0003-2700 (Print) 0003-2700 (Linking)
Abstract:"Comprehensive and time-dependent information (e.g., chemical composition, concentration) of volatile organic compounds (VOCs) in atmospheric, indoor, and breath air is essential to understand the fundamental science of the atmosphere, air quality, and diseases diagnostic. Here, we introduced a fully automated online dynamic in-tube extraction (ITEX)-gas chromatography/mass spectrometry (GC/MS) method for continuous and quantitative monitoring of VOCs in air. In this approach, modified Cycle Composer software and a PAL autosampler controlled and operated the ITEX preconditioning, internal standard (ISTD) addition, air sampling, and ITEX desorption sequentially to enable full automation. Air flow passed through the ITEX with the help of an external pump, instead of plunger up-down strokes, to allow larger sampling volumes, exhaustive extraction, and consequently lower detection limits. Further, in order to evaluate the ITEX system stability and to develop the corresponding quantitative ITEX method, two laboratory-made permeation systems (for standard VOCs and ISTD) were constructed. The stability and suitability of the developed system was validated with a consecutive 19 day atmospheric air campaign under automation. By using an electrospun polyacrylonitrile nanofibers packed ITEX, selective extraction of some VOCs and durability of over 1500 extraction and desorption cycles were achieved. Especially, the latter step is critically important for on-site long-term application at remote regions. This ITEX method provided 2-3 magnitudes lower quantitation limits than the headspace dynamic ITEX method and other needle trap methods. Our results proved the excellence of the fully automated online dynamic ITEX-GC/MS system for tracking VOCs in the atmospheric air"
Keywords:Air Pollutants/*analysis Automation Chemical Fractionation/*methods Gas Chromatography-Mass Spectrometry/*methods Limit of Detection Volatile Organic Compounds/*analysis;
Notes:"MedlineLan, Hangzhen Holopainen, Jani Hartonen, Kari Jussila, Matti Ritala, Mikko Riekkola, Marja-Liisa eng Research Support, Non-U.S. Gov't 2019/06/30 Anal Chem. 2019 Jul 2; 91(13):8507-8515. doi: 10.1021/acs.analchem.9b01668. Epub 2019 Jun 19"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024