Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractElectrospray Ionization Efficiency Is Dependent on Different Molecular Descriptors with Respect to Solvent pH and Instrumental Configuration    Next Abstract"[Distantly received pheromone-primer controls cessation of diapause in the ant Myrmica rubra L. (Hymenoptera, Formicidae)]" »

Anal Bioanal Chem


Title:Analyte and matrix evaporability - key players of low-temperature plasma ionization for ambient mass spectrometry
Author(s):Kiontke A; Engel C; Belder D; Birkemeyer C;
Address:"Institute of Analytical Chemistry, University of Leipzig, Linnestrasse 3, 04103, Leipzig, Germany. andreas.kiontke@uni-leipzig.de. Institute for Medical Informatics, Statistics and Epidemiology (IMISE), Hartelstr. 16-18, 04107, Leipzig, Germany. Institute of Analytical Chemistry, University of Leipzig, Linnestrasse 3, 04103, Leipzig, Germany. Institute of Analytical Chemistry, University of Leipzig, Linnestrasse 3, 04103, Leipzig, Germany. birkemeyer@chemie.uni-leipzig.de"
Journal Title:Anal Bioanal Chem
Year:2018
Volume:20180628
Issue:21
Page Number:5123 - 5130
DOI: 10.1007/s00216-018-1152-1
ISSN/ISBN:1618-2650 (Electronic) 1618-2642 (Linking)
Abstract:"The introduction of ambient ionization at atmospheric pressure for mass spectrometry (AI-MS) attracted the interest of many researchers in the field and various ionization techniques have been described in recent years that allow a quick and easy-to-handle analysis of samples under ambient conditions without or with only minor sample preparation. Among those, plasma-based techniques including the low-temperature plasma probe require very little resources thereby providing great potential for implementation in mobile analytical devices. However, systematic studies on signal responsiveness with this technique, such as the influence of the analyte and matrix characteristics on relative signal intensity, are still rare. Therefore, we used a low-temperature plasma source based on dielectric barrier discharge with helium as process gas to assess influencing factors on signal intensity in mass spectrometry. Among 12 tested molecular descriptors, in particular a low vaporization enthalpy and a large molecular nonpolar surface area improve the relative signal intensity. In addition, we show that the impact of compound characteristics strongly outperforms the influence of simple sample matrices such as different organic solvents and water, with a weak trend that volatile solvents tend to decrease the signal responsiveness of the analytes. However, several specific solvent-analyte interactions occurred, which have to be considered in targeted applications of this method. Our results will help further in improving the implementation and standardization of low-temperature plasma ionization for ambient mass spectrometry and understanding the requirements and selectivity of this technique. Graphical abstract Influencing factors (analyte and matrix characteristics) on signal intensity in dielectric-barrier discharge plasma for ionization in mass spectrometry"
Keywords:Ambient mass spectrometry Aromatic amines Low-temperature plasma ionization Molecular descriptors Optimal signal intensity;
Notes:"PubMed-not-MEDLINEKiontke, Andreas Engel, Christoph Belder, Detlev Birkemeyer, Claudia eng 20015/375/Deutsche Bundesstiftung Umwelt/ Germany 2018/06/29 Anal Bioanal Chem. 2018 Aug; 410(21):5123-5130. doi: 10.1007/s00216-018-1152-1. Epub 2018 Jun 28"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024