Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractLarge herbivores maintain a two-phase herbaceous vegetation mosaic in a semi-arid savanna    Next AbstractEffect of vomeronasal organ removal on male socio-sexual responses to female in a prosimian primate (Microcebus murinus) »

Anal Chem


Title:Design and validation of portable SPME devices for rapid field air sampling and diffusion-based calibration
Author(s):Augusto F; Koziel J; Pawliszyn J;
Address:"Department of Chemistry, University of Waterloo, Ontario, Canada"
Journal Title:Anal Chem
Year:2001
Volume:73
Issue:3
Page Number:481 - 486
DOI: 10.1021/ac000629k
ISSN/ISBN:0003-2700 (Print) 0003-2700 (Linking)
Abstract:"The use of SPME fibers coated with porous polymer solid phases for quantitative purposes is limited due to effects such as interanalyte displacement and competitive adsorption. For air analysis, these problems can be averted by employing short exposure times to air samples flowing around the fiber. In these conditions, a simple mathematical model allows quantification without the need of calibration curves. This work describes two portable dynamic air sampling (PDAS) devices designed for application of this approach to nonequilibrium SPME sampling and determination of airborne volatile organic compounds (VOCs). The use of a PDAS device resulted in greater adsorbed VOC mass compared to the conventional SPME extraction in static air for qualitative screening of live plant aromas and contaminants in indoor air. For all studied air samples, an increase in the number of detected compounds and sensitivity was also observed. Quantification of aromatic VOCs in indoor air was also carried out using this approach and the PDAS/SPME device. Measured VOC concentrations were in low parts-per-billion by volume range using only 30-s SPME fiber exposure and were comparable to those obtained with a standard NIOSH method 1501. The use of PDAS/SPME devices reduced the total air sampling and analysis time by several orders of magnitude compared to the NIOSH 1501 method"
Keywords:
Notes:"PubMed-not-MEDLINEAugusto, F Koziel, J Pawliszyn, J eng 2001/02/24 Anal Chem. 2001 Feb 1; 73(3):481-6. doi: 10.1021/ac000629k"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024