Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCan Volatiles Fingerprints be an Alternative to Isotope Ratio Mass Spectrometry in the Botanical Origin Determination of Spirits?    Next AbstractEffects of maltose and lysine treatment on coffee aroma by flash gas chromatography electronic nose and gas chromatography-mass spectrometry »

Anal Chem


Title:Dielectric barrier discharge-induced chemiluminescence: potential application as GC detector
Author(s):He Y; Lv Y; Li Y; Tang H; Tang L; Wu X; Hou X;
Address:"College of Chemistry, Sichuan University, Chengdu, Sichuan 610064, China"
Journal Title:Anal Chem
Year:2007
Volume:20070510
Issue:12
Page Number:4674 - 4680
DOI: 10.1021/ac070321u
ISSN/ISBN:0003-2700 (Print) 0003-2700 (Linking)
Abstract:"Atmospheric pressure dielectric barrier discharge (DBD) plasma can be used to split low molecular weight organic compounds, and the DBD-split/excited species can be swept into luminol solution to induce chemiluminescence (CL) emission. Based on this observation, a novel optical detector was proposed and preliminarily tested as a potential gas chromatographic (GC) detector in this work. The advantages of this new type of detector include the following: direct detection, fast response, high sensitivity, versatility (sensitive to a broad range of volatile organic compounds), simple and easy instrumentation, compactness (3.0 mm i.d. x 4.0 mm o.d. x 20 mm length of the DBD device), and low power (less than 5 W). Twelve volatile organic compounds, including methanol, ethanol, propanol, formaldehyde, acetaldehyde, benzene, dichloromethane, trichloromethane, tetrachloromethane, tetrahydrofuran, carbon bisulfide, and ethyl ether, were tested with this detector, and each of them produced a large signal. It was found that the CL signal was proportional to the analyte concentration and affected by the DBD parameters. Under the optimized experimental conditions, the limits of detection down to the tens of nanogram level were achieved for methanol, ethanol, propanol, formaldehyde, and acetaldehyde. It was then preliminarily tested as a GC detector for the separation of formaldehyde, ethanol, and propanol. This is the new application of DBD in analytical chemistry, and CL was for the first time generated in this way. The new detector can be a potential GC detector suitable for a wide range of volatile organic compounds"
Keywords:
Notes:"PubMed-not-MEDLINEHe, Yihua Lv, Yi Li, Yaming Tang, Huarong Tang, Li Wu, Xi Hou, Xiandeng eng 2007/05/11 Anal Chem. 2007 Jun 15; 79(12):4674-80. doi: 10.1021/ac070321u. Epub 2007 May 10"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024