Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractChemical reactivities of ambient air samples in three Southern California communities    Next Abstract"Flower Production, Headspace Volatiles, Pollen Nutrients, and Florivory in Tanacetum vulgare Chemotypes" »

J Chem Ecol


Title:Novel Set-Up for Low-Disturbance Sampling of Volatile and Non-volatile Compounds from Plant Roots
Author(s):Eilers EJ; Pauls G; Rillig MC; Hansson BS; Hilker M; Reinecke A;
Address:"Department of Applied Zoology/Animal Ecology, Freie Universitat Berlin, Haderslebener Strasse 9, 12163, Berlin, Germany, eeilers@zedat.fu-berlin.de"
Journal Title:J Chem Ecol
Year:2015
Volume:20150322
Issue:3
Page Number:253 - 266
DOI: 10.1007/s10886-015-0559-9
ISSN/ISBN:1573-1561 (Electronic) 0098-0331 (Print) 0098-0331 (Linking)
Abstract:"Most studies on rhizosphere chemicals are carried out in substrate-free set-ups or in artificial substrates using sampling methods that require an air flow and may thus cause disturbance to the rhizosphere. Our study aimed to develop a simplified and inexpensive system that allows analysis of rhizosphere chemicals at experimentally less disturbed conditions. We designed a mesocosm in which volatile rhizosphere chemicals were sampled passively (by diffusion) without air- and water flow on polydimethylsiloxane-(PDMS) tubes. Dandelion (Taraxacum sect. ruderalia) was used as model plant; roots were left undamaged. Fifteen volatiles were retrieved from the sorptive material by thermal desorption for analysis by gas chromatography/mass spectrometry (GC/MS). Furthermore, three sugars were collected from the rhizosphere substrate by aqueous extraction and derivatized prior to GC/MS analysis. In order to study how the quantity of detected rhizosphere compounds depends on the type of soil or substrate, we determined the matrix-dependent recovery of synthetic rhizosphere chemicals. Furthermore, we compared sorption of volatiles on PDMS tubes with and without direct contact to the substrate. The results show that the newly designed mesocosm is suitable for low-invasive extraction of volatile and non-volatile compounds from rhizospheres. We further highlight how strongly the type of substrate and contact of PDMS tubes to the substrate affect the detectability of compounds from rhizospheres"
Keywords:"Analytic Sample Preparation Methods/economics/*methods Dimethylpolysiloxanes/chemistry Environment, Controlled Gas Chromatography-Mass Spectrometry Hydrophobic and Hydrophilic Interactions Plant Roots/*chemistry Rhizosphere Soil/chemistry Taraxacum/chemis;"
Notes:"MedlineEilers, Elisabeth J Pauls, Gerhard Rillig, Matthias C Hansson, Bill S Hilker, Monika Reinecke, Andreas eng Research Support, Non-U.S. Gov't 2015/03/22 J Chem Ecol. 2015 Mar; 41(3):253-66. doi: 10.1007/s10886-015-0559-9. Epub 2015 Mar 22"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 06-07-2024