Title:Determination of the Clean Air Delivery Rate (CADR) of Photocatalytic Oxidation (PCO) Purifiers for Indoor Air Pollutants Using a Closed-Loop Reactor. Part I: Theoretical Considerations
Author(s):Dumont E; Hequet V;
Address:"UMR CNRS 6144 GEPEA, IMT Atlantique, La Chantrerie, 4 rue Alfred Kastler, CS 20722, 44307 Nantes CEDEX 3, France. eric.dumont@imt-atlantique.fr. UMR CNRS 6144 GEPEA, IMT Atlantique, La Chantrerie, 4 rue Alfred Kastler, CS 20722, 44307 Nantes CEDEX 3, France. valerie.hequet@imt-atlantique.fr"
Journal Title:Molecules
Year:2017
Volume:20170306
Issue:3
Page Number: -
DOI: 10.3390/molecules22030407
ISSN/ISBN:1420-3049 (Electronic) 1420-3049 (Linking)
Abstract:"This study demonstrated that a laboratory-scale recirculation closed-loop reactor can be an efficient technique for the determination of the Clean Air Delivery Rate (CADR) of PhotoCatalytic Oxidation (PCO) air purification devices. The recirculation closed-loop reactor was modeled by associating equations related to two ideal reactors: one is a perfectly mixed reservoir and the other is a plug flow system corresponding to the PCO device itself. Based on the assumption that the ratio between the residence time in the PCO device and the residence time in the reservoir tau(P)/tau(R) tends to 0, the model highlights that a lab closed-loop reactor can be a suitable technique for the determination of the efficiency of PCO devices. Moreover, if the single-pass removal efficiency is lower than 5% of the treated flow rate, the decrease in the pollutant concentration over time can be characterized by a first-order decay model in which the time constant is proportional to the CADR. The limits of the model are examined and reported in terms of operating conditions (experiment duration, ratio of residence times, and flow rate ranges)"
Keywords:"*Air Filters/standards Air Pollution, Indoor/*analysis Algorithms Catalysis Models, Theoretical Oxidation-Reduction Photochemistry/*methods Volatile Organic Compounds Volatile Organic Compounds (VOCs) air cleaner clean air delivery rate (CADR) indoor air;"
Notes:"MedlineDumont, Eric Hequet, Valerie eng Switzerland 2017/03/09 Molecules. 2017 Mar 6; 22(3):407. doi: 10.3390/molecules22030407"

 