Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPurification and characterization of an extracellular peptide factor that affects two different developmental pathways in Bacillus subtilis    Next AbstractTranscriptome profiles of Quercus rubra responding to increased O(3) stress »

J Am Soc Mass Spectrom


Title:"A preconcentrator coupled to a GC/FTMS: advantages of self-chemical ionization, mass measurement accuracy, and high mass resolving power for GC applications"
Author(s):Solouki T; Szulejko JE; Bennett JB; Graham LB;
Address:"Department of Chemistry, University of Maine, Orono, Maine 04469, USA. solouki@maine.edu"
Journal Title:J Am Soc Mass Spectrom
Year:2004
Volume:15
Issue:8
Page Number:1191 - 1200
DOI: 10.1016/j.jasms.2004.03.003
ISSN/ISBN:1044-0305 (Print) 1044-0305 (Linking)
Abstract:"Coupling of a cryogenic preconcentrator (PC) to a gas chromatograph/Fourier transform ion cyclotron resonance mass spectrometer (GC/FT-ICR MS) is reported. To demonstrate the analytical capabilities of the PC/GC/FT-ICR MS, headspace samples containing volatile organic compounds (VOCs) emitted from detached pine tree twigs were analyzed. Sub-ppm mass measurement accuracy (MMA) for highly resolved (m/Deltam(50%) > 150 k) terpene ions was achieved. Direct PC/GC/FT-ICR MS analyses revealed that detached twigs from pine trees emit acetone, camphor, and four detectable hydrocarbon isomers with C(10)H(16) empirical formula. The unknown analytes were identified based on accurate mass measurement and their mass spectral appearances. Authentic samples were used to confirm initially unknown identifications. Self-chemical-ionization (SCI) reactions furnished an additional dimension for rapid isomer differentiation of GC eluents in real time"
Keywords:"Cyclotrons Flame Ionization Gas Chromatography-Mass Spectrometry/*methods Hydrocarbons/analysis Molecular Weight Pinus/chemistry Reproducibility of Results Spectroscopy, Fourier Transform Infrared Volatilization Wood;"
Notes:"MedlineSolouki, Touradj Szulejko, Jan E Bennett, Justin B Graham, LeRae B eng Research Support, U.S. Gov't, Non-P.H.S. 2004/07/28 J Am Soc Mass Spectrom. 2004 Aug; 15(8):1191-200. doi: 10.1016/j.jasms.2004.03.003"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-06-2024