Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractField survey of indoor air quality in detached houses in Niigata Prefecture    Next Abstract"Annual transition and seasonal variation of indoor air pollution levels of 2-ethyl-1-hexanol in large-scale buildings in Nagoya, Japan" »

Environ Res


Title:"A comparison of indoor air pollutants in Japan and Sweden: formaldehyde, nitrogen dioxide, and chlorinated volatile organic compounds"
Author(s):Sakai K; Norback D; Mi Y; Shibata E; Kamijima M; Yamada T; Takeuchi Y;
Address:"Nagoya City Public Health Research Institute, 1-11 Hagiyama-cho, Mizuho-ku, Nagoya 467-8615, Japan. ehdeiken@sa.starcat.net"
Journal Title:Environ Res
Year:2004
Volume:94
Issue:1
Page Number:75 - 85
DOI: 10.1016/s0013-9351(03)00140-3
ISSN/ISBN:0013-9351 (Print) 0013-9351 (Linking)
Abstract:"Indoor and outdoor concentrations of formaldehyde (HCHO), nitrogen dioxide (NO2), and selected chlorinated volatile organic compounds (chlorinated VOC) were measured in 37 urban dwellings in Nagoya, Japan, and 27 urban dwellings in Uppsala, Sweden, using the same sampling procedures and analytical methods. Indoor as well as outdoor air concentrations of HCHO, NO2, and chlorinated VOC were significantly higher in Nagoya than in Uppsala (P<0.01), with the exception of tetrachlorocarbon in outdoor air. In Nagoya, HCHO and NO2 concentrations were significantly higher in modern concrete houses than in wooden houses and higher in newer (less than 10 years) than in older dwellings (P<0.01), possibly due to less natural ventilation and more emission sources in modern buildings. Dwellings heated with unvented combustion sources had significantly higher indoor concentrations of NO2 than those with clean heating (P<0.05). Moreover, dwellings with moth repellents containing p-dichlorobenzene had significantly higher indoor concentrations of p-dichlorobenzene (P<0.01). In conclusion, there appear to be differences between Nagoya and Uppsala with respect to both indoor and outdoor pollution levels of the measured pollutants. More indoor pollution sources could be identified in Nagoya than in Uppsala, including construction and interior materials emitting VOC, use of unvented combustion space heaters, and moth repellents containing p-dichlorobenzene"
Keywords:"Air Pollutants/*analysis Air Pollution, Indoor/*analysis Chlorine Compounds/analysis Construction Materials Environmental Exposure/*analysis Environmental Monitoring Formaldehyde/analysis *Housing Humans Japan Nitrogen Dioxide/analysis Sweden Urban Health;"
Notes:"MedlineSakai, Kiyoshi Norback, Dan Mi, Yahong Shibata, Eiji Kamijima, Michihiro Yamada, Tetsuya Takeuchi, Yasuhiro eng Comparative Study Research Support, Non-U.S. Gov't Netherlands 2003/12/04 Environ Res. 2004 Jan; 94(1):75-85. doi: 10.1016/s0013-9351(03)00140-3"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-12-2024