Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractFunctional imaging and quantification of multineuronal olfactory responses in C. elegans    Next AbstractApplications of open-path Fourier transform infrared for identification of volatile organic compound pollution sources and characterization of source emission behaviors »

J Air Waste Manag Assoc


Title:Fugitive coke oven gas emission profile by continuous line averaged open-path Fourier transform infrared monitoring
Author(s):Lin C; Liou N; Chang PE; Yang JC; Sun E;
Address:"Department of Marine Environmental Engineering, National Kaohsiung Marine University, Kaohsiung, Taiwan, Republic of China. ctlin@mail.nkmu.edu.tw"
Journal Title:J Air Waste Manag Assoc
Year:2007
Volume:57
Issue:4
Page Number:472 - 479
DOI: 10.3155/1047-3289.57.4.472
ISSN/ISBN:1096-2247 (Print) 1096-2247 (Linking)
Abstract:"Although most coke oven research is focused on the emission of polycyclic aromatic hydrocarbons, well-known carcinogens, little has been done on the emission of volatile organic compounds, some of which are also thought to be hazardous to workers and the environment. To profile coke oven gas (COG) emissions, we set up an open-path Fourier transform infrared (OP-FTIR) system on top of a battery of coke ovens at a steel mill located in Southern Taiwan and monitored average emissions in a coke processing area for 16.5 hr. Nine COGs were identified, including ammonia, CO, methane, ethane, ethylene, acetylene, propylene, cyclohexane, and O-xylene. Time series plots indicated that the type of pollutants differed over time, suggesting that different emission sources (e.g., coke pushing, quench tower, etc.) were involved at different times over the study period. This observation was confirmed by the low cross-correlation coefficients of the COGs. It was also found that, with the help of meteorological analysis, the data collected by the OP-FTIR system could be analyzed effectively to characterize differences in the location of sources. Although the traditional single-point samplings of emissions involves sampling various sources in a coke processing area at several different times and is a credible profiling of emissions, our findings strongly suggest that they are not nearly as efficient or as cost-effective as the continuous line average method used in this study. This method would make it easier and cheaper for engineers and health risk assessors to identify and to control fugitive volatile organic compound emissions and to improve environmental health"
Keywords:"Air Pollutants/*analysis Air Pollutants, Occupational/*analysis Air Pollution/prevention & control *Coke Cost-Benefit Analysis *Environmental Health Environmental Monitoring/economics/*methods Gases/analysis Humans Metallurgy Meteorological Concepts Occup;"
Notes:"MedlineLin, Chitsan Liou, Naiwei Chang, Pao-Erh Yang, Jen-Chin Sun, Endy eng Comparative Study 2007/04/27 J Air Waste Manag Assoc. 2007 Apr; 57(4):472-9. doi: 10.3155/1047-3289.57.4.472"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 03-07-2024