Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractGraphene-based hybrid structures combined with functional materials of ferroelectrics and semiconductors    Next AbstractCYP2E1 phenotype in Mexican workers occupationally exposed to low levels of toluene »

Environ Sci Process Impacts


Title:Emerging investigator series: air conditioning filters as a sampler for semi-volatile organic compounds in indoor and near-building air
Author(s):Jilkova SR; Melymuk L; Klanova J;
Address:"RECETOX, Masaryk University, Brno, Czech Republic. lisa.melymuk@recetox.muni.cz"
Journal Title:Environ Sci Process Impacts
Year:2020
Volume:22
Issue:12
Page Number:2322 - 2331
DOI: 10.1039/d0em00284d
ISSN/ISBN:2050-7895 (Electronic) 2050-7887 (Linking)
Abstract:"Organic compounds like flame retardants (FRs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polycyclic aromatic hydrocarbons (PAHs) are consistently found in both indoor and outdoor environments. There are many possible matrices for measurement of these compounds (e.g. indoor dust, air - passive and active air samples), but all methods have limitations, like the heterogeneous distribution of indoor dust, or noisy active air samplers. We used filters from building-wide heating, ventilation and air conditioning (HVAC) units to evaluate levels of PAHs, PCBs, OCPs and NFRs in indoor and outdoor environments, and to evaluate whether this method is feasible for screening semivolatile organic compounds (SVOCs) in indoor and near-building outdoor environments. Detectable levels of FRs, PCBs, OCPs and PAHs were found, demonstrating that HVAC filters do collect SVOCs, with generally higher levels of PAHs in the incoming air filters and higher levels of PCBs, OCPs and FRs in the outgoing air filters. Levels of FRs, PCBs and OCPs in outgoing air were comparable to those measured using conventional active air sampling in the same building. The advantages of using HVAC filters are (1) integrated and homogeneous samples, as the whole building is sampled over typically a long timescale (months), and (2) samples are easy and cheap to collect and do not require prior deployment of samplers. The key disadvantage is that HVAC filters are not designed for analytical chemistry and thus the filter materials can have variable or unknown gas sorption and particle capture, and can have strong matrix effects during analysis"
Keywords:"Air Conditioning *Air Filters *Air Pollutants/analysis *Air Pollution, Indoor/analysis Environmental Monitoring *Flame Retardants/analysis *Polychlorinated Biphenyls/analysis *Polycyclic Aromatic Hydrocarbons/analysis *Volatile Organic Compounds/analysis;"
Notes:"MedlineJilkova, Simona Rozarka Melymuk, Lisa Klanova, Jana eng England 2020/11/02 Environ Sci Process Impacts. 2020 Dec 16; 22(12):2322-2331. doi: 10.1039/d0em00284d"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 05-12-2024