Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractComparative transcriptome analysis reveals an insight into the candidate genes involved in anthocyanin and scent volatiles biosynthesis in colour changing flowers of Combretum indicum    Next AbstractExposure to Volatile Organic Compounds in Paint Production Plants: Levels and Potential Human Health Risks »

Ind Health


Title:"A field method for sampling toluene in end-exhaled air, as a biomarker of occupational exposure: correlation with other exposure indices"
Author(s):Ghittori S; Alessio A; Negri S; Maestri L; Zadra P; Imbriani M;
Address:"Fondazione S. Maugeri, Clinica del Lavoro e della Riabilitazione, IRCCS-Istituto Scientifico di Pavia, Via Ferrata 8, 27100 Pavia, Italy"
Journal Title:Ind Health
Year:2004
Volume:42
Issue:2
Page Number:226 - 234
DOI: 10.2486/indhealth.42.226
ISSN/ISBN:0019-8366 (Print) 0019-8366 (Linking)
Abstract:"A sensitive and rapid method for the determination of toluene in exhaled air is described. We have developed a device for direct breath sampling consisting of a sampler inserted into an empty 58 mL glass vial closed by a Teflon rubber septum. The sorbent cartridge functions as a diffusive sampler and employs a Tenax resin (300 mg, 35/50 mesh) to trap volatile organic compounds from the exhaled air. End-exhaled air is collected 'in field' by removing the septum from the vial, by forcibly exhaling into the device through a suitable Teflon tube, and then by sealing the bottle quickly. Environmental toluene levels ranged from 13 to 191 mg/m3, while the concentrations of the solvent in alveolar air, in blood and urine ranged from 159 to 3354 ng/L, from 3.6 to 53.5 microg/L, and from 8.7 to 142.4 microg/L respectively. The correlation coefficients (r) of biological measurements towards environmental toluene levels were 0.822, 0.850 and 0.846 for alveolar air, blood and urine samples, respectively. The breath sampler allowed the rapid and non-invasive collection of data on elimination of toluene"
Keywords:Adult Biomarkers/analysis Breath Tests/instrumentation/*methods Environmental Monitoring/instrumentation/*methods Humans Male Occupational Exposure/*analysis Reproducibility of Results Sensitivity and Specificity Toluene/*analysis;
Notes:"MedlineGhittori, Sergio Alessio, Alberto Negri, Sara Maestri, Luciano Zadra, Paola Imbriani, Marcello eng Clinical Trial Comparative Study Validation Study Japan 2004/05/07 Ind Health. 2004 Apr; 42(2):226-34. doi: 10.2486/indhealth.42.226"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024