Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractExhaled volatile organic compounds in individuals with a history of high altitude pulmonary edema and varying hypoxia-induced responses    Next AbstractExposure to genotoxic compounds alters in vitro cellular VOC excretion »

J Breath Res


Title:The necessity of external validation in exhaled breath research: a case study of sarcoidosis
Author(s):Fijten RRR; Smolinska A; Drent M; Dallinga JW; Mostard R; Pachen DM; van Schooten FJ; Boots AW;
Address:"Department of Pharmacology & Toxicology, School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, Netherlands"
Journal Title:J Breath Res
Year:2017
Volume:20171129
Issue:1
Page Number:16004 -
DOI: 10.1088/1752-7163/aa8409
ISSN/ISBN:1752-7163 (Electronic) 1752-7155 (Linking)
Abstract:"As in other disciplines of 'omics' research, reproducibility is a major problem in exhaled breath research. Many studies report discriminatory volatiles in the same disease, yet the similarity between lists of identified compounds is low. This can occur due to many factors including the lack of internal and, in particular, external validation. In an ideal situation, an external validation-sampled at, for example, a different location-is always included to ensure generalization of the observed findings to a general population. In this study, we hypothesized that sarcoidosis patients and healthy controls could be discriminated based on a group of volatile organic compounds (VOCs) in exhaled breath and that these discriminating VOCs could be validated in an external population. The first dataset consisted of 87 sarcoidosis patients and 27 healthy controls, whereas the validation dataset consisted of 25 patients and 29 controls. Using the first dataset, nine VOCs were found that could predict sarcoidosis with 79.4% accuracy. Different types of internal and external validation were tested to assess the validity of the nine VOCs. Of the internal validations, randomly setting aside part of the data achieved the most accurate predictions while external validation was only possible by building a new prediction model that yielded a promising yet not entirely convincing accuracy of 74% due to the indirect approach. In conclusion, the initial results of this study are very promising but, as the results of our validation set already indicated, may not be reproducible in other studies. In order to achieve a reliable diagnostic breath fingerprint for sarcoidosis, we encourage other scientists to validate the presented findings. TRIAL REGISTRATION: NCT00741572 & NCT02361281"
Keywords:Breath Tests/*methods Case-Control Studies Discriminant Analysis *Exhalation Female Humans Least-Squares Analysis Male Middle Aged ROC Curve Reproducibility of Results Sarcoidosis/*diagnosis Volatile Organic Compounds/analysis;
Notes:"MedlineFijten, Rianne R R Smolinska, Agnieszka Drent, Marjolein Dallinga, Jan W Mostard, Remy Pachen, Danielle M van Schooten, Frederik J Boots, Agnes W eng Research Support, Non-U.S. Gov't Validation Study England 2017/08/05 J Breath Res. 2017 Nov 29; 12(1):016004. doi: 10.1088/1752-7163/aa8409"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024