Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractBreath analysis for colorectal cancer screening    Next AbstractAtmospheric Degradation of Cyclic Volatile Methyl Siloxanes: Radical Chemistry and Oxidation Products »

BJS Open


Title:Chemical signature of colorectal cancer: case-control study for profiling the breath print
Author(s):Altomare DF; Picciariello A; Rotelli MT; De Fazio M; Aresta A; Zambonin CG; Vincenti L; Trerotoli P; De Vietro N;
Address:"Surgical Unit 'M. Rubino', Department of Emergency and Organ Transplantation, Bari, Italy. Apulian Breath Analysis Centre (CeRBA), Istituto Di Ricovero e Cura a Carattere Scientifico (IRCCS) Istituto Tumori Giovanni Paolo II, Bari, Italy. Department of Chemistry, University Aldo Moro of Bari, Bari, Italy. Surgical Unit, Azienda Ospedaliero-Universitaria Policlinico Bari, Bari, Italy. Statistical Unit, Department of Biomedical Sciences and Human Oncology, Bari, Italy"
Journal Title:BJS Open
Year:2020
Volume:20200929
Issue:6
Page Number:1189 - 1199
DOI: 10.1002/bjs5.50354
ISSN/ISBN:2474-9842 (Electronic) 2474-9842 (Linking)
Abstract:"BACKGROUND: Effective screening for colorectal cancer can reduce mortality by early detection of tumours and colonic polyps. An altered pattern of volatile organic compounds (VOCs) in exhaled breath has been proposed as a potential non-invasive diagnostic tool for detection of cancer. The aim of this study was to evaluate the reliability of breath-testing for colorectal cancer screening and early diagnosis using an advanced breath sampler. METHODS: The exhaled breath of patients with colorectal cancer and non-cancer controls with negative findings on colonoscopy was collected using the ReCIVA(R) Breath Sampler. This portable device is able to capture the alveolar breath fraction without environmental contamination. VOCs were desorbed thermally and analysed by gas chromatography-mass spectrometry. The discriminatory ability of VOCs in detecting colorectal cancer was evaluated by receiver operating characteristic (ROC) curve analysis for each VOC, followed by cross-validation by the leave-one-out method, and by applying stepwise logistic regression analysis. RESULTS: The study included 83 patients with colorectal cancer and 90 non-cancer controls. Fourteen VOCs were found to have significant discriminatory ability in detecting patients with colorectal cancer. The model with the diagnosis of cancer versus no cancer resulted in a statistically significant likelihood of discrimination of 173.45 (P < 0.001), with an area under the ROC curve of 0.979. Cross-validation of the model resulted in a true predictive value for colorectal cancer of 93 per cent overall. Reliability of the breath analysis was maintained irrespective of cancer stage. CONCLUSION: This study demonstrated that analysis of exhaled VOCs can discriminate patients with colorectal cancer from those without. This finding may eventually lead to the creation of a smart online sensory device, capable of providing a binary answer (cancer/no cancer) and directing to further screening"
Keywords:
Notes:"PublisherAltomare, D F Picciariello, A Rotelli, M T De Fazio, M Aresta, A Zambonin, C G Vincenti, L Trerotoli, P De Vietro, N eng England 2020/09/30 BJS Open. 2020 Sep 29; 4(6):1189-99. doi: 10.1002/bjs5.50354"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-09-2024