Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAlarm pheromones do not mediate rapid shifts in honey bee guard acceptance threshold    Next AbstractHouston's rapid ozone increases: preconditions and geographic origins »

J Air Waste Manag Assoc


Title:"Assessment of a regulatory model's performance relative to large spatial heterogeneity in observed ozone in Houston, Texas"
Author(s):Couzo E; Olatosi A; Jeffries HE; Vizuete W;
Address:"Department of Environmental Sciences and Engineering, University of North Carolina Gillings School of Global Public Health, CB 7431, Chapel Hill, NC 27599, USA"
Journal Title:J Air Waste Manag Assoc
Year:2012
Volume:62
Issue:6
Page Number:696 - 706
DOI: 10.1080/10962247.2012.667050
ISSN/ISBN:1096-2247 (Print) 1096-2247 (Linking)
Abstract:"In Houston, some of the highest measured 8-hr ozone (O3) peaks are characterized by sudden increases in observed concentrations of at least 40 ppb in 1 hr or 60 ppb in 2 hr. Measurements show that these large hourly changes appear at only a few monitors and span a narrow geographic area, suggesting a spatially heterogeneous field of O3 concentrations. This study assessed whether a regulatory air quality model (AQM) can simulate this observed behavior. The AQM did not reproduce the magnitude or location of some of the highest observed hourly O3 changes, and it also failed to capture the limited spatial extent. On days with measured large hourly changes in O3 concentrations, the AQM predicted high O3 over large regions of Houston, resulting in overpredictions at several monitors. This analysis shows that the model can make high O3, but on these days the predicted spatial field suggests that the model had a different cause. Some observed large hourly changes in O3 concentrations have been linked to random releases of industrial volatile organic compounds (VOCs). In the AQM emission inventory, there are several emission events when an industrial point source increases VOC emissions in excess of 10,000 mol/hr. One instance increased predicted downwind O3 concentrations up to 25 ppb. These results show that the modeling system is responsive to a large VOC release, but the timing and location of the release, and meteorological conditions, are critical requirements. Attainment of the O3 standard requires the use of observational data and AQM predictions. If the large observed hourly changes are indicative of a separate cause of high O3, then the model may not include that cause, which might result in regulators enacting control strategies that could be ineffective"
Keywords:"Air Pollutants/*chemistry Air Pollution Cities *Environmental Monitoring *Models, Chemical Ozone/*chemistry Texas Time Factors;"
Notes:"MedlineCouzo, Evan Olatosi, Adeola Jeffries, Harvey E Vizuete, William eng 2012/07/14 J Air Waste Manag Assoc. 2012 Jun; 62(6):696-706. doi: 10.1080/10962247.2012.667050"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024