Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDeveloping monitoring techniques for the invasive goldspotted oak borer (Coleoptera: Buprestidae) in California    Next AbstractEnhancement of volatile aglycone recovery facilitated by acid hydrolysis of glucosides from Nicotiana flower species »

J Air Waste Manag Assoc


Title:A Gas Chromatographic Continuous Emissions Monitoring System for the Determination of VOCs and HAPs
Author(s):Coleman WM; Gordon BM;
Address:"a Research Department, R. J. Reynolds Tobacco Company , Winston-Salem , NC"
Journal Title:J Air Waste Manag Assoc
Year:1996
Volume:46
Issue:1
Page Number:30 - 34
DOI: 10.1080/10473289.1996.10467438
ISSN/ISBN:2162-2906 (Electronic) 1096-2247 (Linking)
Abstract:"This article describes a new gas chromatography-based emissions monitoring system for measuring volatile organic compounds (VOCs) and hazardous air pollutants (HAPs). The system is composed of a dual-column gas chromatograph equipped with thermal conductivity detectors, in which separation is optimized for fast chromatography. The system has the necessary valving for stream selection, which allows automatic calibration of the system at predetermined times and successive measurement of individual VOCs before and after a control device. Nine different VOCs (two of which are HAPs), plus methane (CH4) and carbon dioxide (CO2) are separated and quantified every two minutes. The accuracy and precision of this system has been demonstrated to be greater than 95%. The system employs a mass flow measurement device and also calculates and displays processed emission data, such as control device efficiency and total weight emitted during given time periods. Two such systems have been operational for one year in two separate gravure printing facilities; minimal upkeep is required, about one hour per month. One of these systems, used before and after a carbon adsorber, has been approved by the pertinent local permitting authority"
Keywords:
Notes:"PubMed-not-MEDLINEColeman, William M III Gordon, Bert M eng 1996/01/01 J Air Waste Manag Assoc. 1996 Jan; 46(1):30-34. doi: 10.1080/10473289.1996.10467438"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024