Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVolatile components of ethanolic extract from broccolini leaves    Next Abstract"Small-Area, Resistive Volatile Organic Compound (VOC) Sensors Using Metal-Polymer Hybrid Film Based on Oxidative Chemical Vapor Deposition (oCVD)" »

J Sep Sci


Title:Trace analysis of alkaline flavors in cut tobacco by heart-cutting multidimensional GC-GC-MS
Author(s):Wang X; Liu S; Xia Q; Zhao G; Guo J; Xie F;
Address:"Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou, P. R. China"
Journal Title:J Sep Sci
Year:2013
Volume:20131014
Issue:23
Page Number:3750 - 3757
DOI: 10.1002/jssc.201300836
ISSN/ISBN:1615-9314 (Electronic) 1615-9306 (Linking)
Abstract:"Tobacco is a complex chemical matrix. The analysis of trace alkaline flavors in tobacco is very difficult because of the limited peak capacity of monodimensional GC. In the present study, a home-assembled twin-oven GC-GC-MS system, with MS detection in both dimensions, has been applied to the analysis of 20 alkaline volatiles in a variety of cut-tobacco samples. By transferring nine and six heart-cuts from the first apolar column to the second polar column in two separate runs, the potential mutual interference of adjacent isomeric targets and the complex matrix could be removed. For comparative purposes, a systematic comparison of both quantification and qualification results for the cut-tobacco sample as quality control was conducted between GC-GC-MS and GC-MS. The results showed that GC-GC-MS provided higher accuracy in peak assignment and quantification. And in GC-MS, the interferences of co-elution had caused both low matched similarity in peak assignment and false-negative/-positive results in quantification for some targets. Advantages of the developed GC-GC-MS method in the analysis of alkaline flavors are its high resolving power, reliability, and simplicity"
Keywords:*Gas Chromatography-Mass Spectrometry Reproducibility of Results Tobacco/*chemistry Volatile Organic Compounds/chemistry Alkaline flavors Cut tobacco Heart cuts Multidimensional GC;
Notes:"MedlineWang, Xiaoyu Liu, Shaofeng Xia, Qiaoling Zhao, Ge Guo, Jizhao Xie, Fuwei eng Research Support, Non-U.S. Gov't Germany 2013/10/12 J Sep Sci. 2013 Dec; 36(23):3750-7. doi: 10.1002/jssc.201300836. Epub 2013 Oct 14"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 22-09-2024