« Previous AbstractRapid temperature-programmed separation of carbon monoxide and carbon dioxide on a packed capillary column in gas chromatography: application to the evaluation of photocatalytic activity of TiO2    Next Abstract"Quantitative Determination of 2-Ethyl-1-hexanol, Texanol and TXIB in In-door Air Using a Solid-Phase Extraction-type Collection Device Followed by Gas Chromatography-Mass Spectrometry" »

Anal Sci


Title:Quantitative Determination of Phthalate Esters from Air Samples Using a Solid-Phase Extraction-type Collection Device
Author(s):Ueta I; Takenaka R; Fujimura K; Yoshimura T; Narukami S; Mochizuki S; Sasaki T; Maeda T;
Address:"Department of Applied Chemistry, University of Yamanashi. Shinwa Chemical Industries Ltd. HORIBA STEC, Co., Ltd. Professionals' Network in Advanced Instrumentation Society (PAI-NET)"
Journal Title:Anal Sci
Year:2018
Volume:20180608
Issue:10
Page Number:1149 - 1153
DOI: 10.2116/analsci.18P175
ISSN/ISBN:1348-2246 (Electronic) 0910-6340 (Linking)
Abstract:"In this study, a solid-phase extraction-type collection device, with styrene-divinylbenzene polymer particles (Sunpak-H) as the adsorbent, was used for the quantitative determination of phthalate esters in air samples. The collection and elution recoveries of eight volatile phthalate esters, i.e., dimethyl phthalate, diethyl phthalate, dipropyl phthalate, diisobutyl phthalate, dibutyl phthalate, butyl-benzyl phthalate, di(2-ethylhexyl) phthalate, and dioctyl phthalate, were quantitatively evaluated. All analytes were collected using the device up to a sampling volume of 10000 L at a sampling temperature of 35 degrees C without breakthrough. During air collection, moisture was not trapped on the adsorbent. The collected analytes were completely eluted from the device by passing 3 mL of acetone. The eluted solvent was injected into a gas chromatography-mass spectrometry system after the eluted solvent was concentrated, if necessary. After washing the adsorbent using acetone, the device could be reused more than 50 times. The limit of quantification for the analytes was less than 1 ng L(-1) in air at a sampling volume of 600 L with solvent concentration. This device was successfully applied for the quantitative determination of phthalate esters in real air samples, including indoor and in-car air"
Keywords:Adsorption Air/*analysis Esters/*chemistry Phthalic Acids/*analysis/*chemistry/isolation & purification Solid Phase Extraction/*instrumentation Phthalate ester gas chromatography-mass spectrometry sample preparation semi-volatile organic compounds;
Notes:"MedlineUeta, Ikuo Takenaka, Risa Fujimura, Koji Yoshimura, Tomotaka Narukami, Shoji Mochizuki, Suguru Sasaki, Tomohiro Maeda, Tsuneaki eng Switzerland 2018/06/12 Anal Sci. 2018 Oct 10; 34(10):1149-1153. doi: 10.2116/analsci.18P175. Epub 2018 Jun 8"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 28-12-2024