Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractWith a splash of VOCs (volatile organic compounds). Chemicals found in many cities' ground water    Next AbstractVolatile compounds in health and disease »

Eur J Mass Spectrom (Chichester)


Title:Selected ion flow tube mass spectrometry for on-line trace gas analysis in biology and medicine
Author(s):Spanel P; Smith D;
Address:"J. Heyrovsky Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejskova 3, Prague, 18223 Czech Republic"
Journal Title:Eur J Mass Spectrom (Chichester)
Year:2007
Volume:13
Issue:1
Page Number:77 - 82
DOI: 10.1255/ejms.843
ISSN/ISBN:1469-0667 (Print) 1469-0667 (Linking)
Abstract:"Selected ion flow tube mass spectrometry, (SIFT-MS), is a technique for simultaneous real-time quantification of several trace gases in air and exhaled breath. It relies on chemical ionization of the trace gas molecules in air/breath samples introduced into helium carrier gas, using H(3)O(+), NO(+) and O(2)(+) reagent (precursor ions). Reactions between the precursor ions and the trace gas molecules proceed for an accurately defined time, the precursor and product ions being detected and counted by a downstream mass spectrometer. Absolute concentrations of trace gases in single breath exhalation can be determined by SIFT-MS down to parts-per-billion (ppb) levels, obviating sample collection into bags or onto traps. Calibration using chemical standards is not required, as the concentrations are calculated using the known reaction rate constants and measured flow rates and pressures. SIFT-MS has been used for many pilot investigations in several areas of research, especially as a non-invasive breath analysis tool to investigate physiological processes in humans and animals, for clinical diagnosis and for therapeutic monitoring. Examples of the results obtained from several such studies are outlined to demonstrate the potential of SIFT-MS for trace gas analysis of air, exhaled breath and the headspace above liquids"
Keywords:Animals Breath Tests/instrumentation/methods Cattle Clinical Chemistry Tests Gases/*chemistry Humans Mass Spectrometry/instrumentation/*methods Point-of-Care Systems;
Notes:"MedlineSpanel, P Smith, D eng Research Support, Non-U.S. Gov't Review England 2007/09/20 Eur J Mass Spectrom (Chichester). 2007; 13(1):77-82. doi: 10.1255/ejms.843"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 23-09-2024