Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractOn-site monitoring of biogenic emissions from Eucalyptus dunnii leaves using membrane extraction with sorbent interface combined with a portable gas chromatograph system    Next AbstractWheat gene expression is differentially affected by a virulent Russian wheat aphid biotype »

Anal Bioanal Chem


Title:Preliminary studies of using preheated carrier gas for on-line membrane extraction of semivolatile organic compounds
Author(s):Liu X; Pawliszyn J;
Address:"Department of Chemistry, University of Waterloo, Waterloo, ON, N2L 3G1, Canada"
Journal Title:Anal Bioanal Chem
Year:2007
Volume:20070210
Issue:7
Page Number:2517 - 2525
DOI: 10.1007/s00216-007-1120-7
ISSN/ISBN:1618-2642 (Print) 1618-2642 (Linking)
Abstract:"In this paper, we present results for the on-line determination of semivolatile organic compounds (SVOCs) in air using membrane extraction with a sorbent interface-ion mobility spectrometry (MESI-IMS) system with a preheated carrier (stripping) gas. The mechanism of the mass transfer of SVOCs across a membrane was initially studied. In comparison with the extraction of volatile analytes, the mass transfer resistance that originated from the slow desorption from the internal membrane surface during the SVOC extraction processes should be taken into account. A preheated carrier gas system was therefore built to facilitate desorption of analytes from the internal membrane surface. With the benefit of a temperature gradient existing between the internal and external membrane surfaces, an increase in the desorption rate of a specific analyte at the internal surface and the diffusion coefficient within the membrane could be achieved while avoiding a decrease of the distribution constant on the external membrane interface. This technique improved both the extraction rate and response times of the MESI-IMS system for the analysis of SVOCs. Finally, the MESI-IMS system was shown to be capable of on-site measurement by monitoring selected polynuclear aromatic hydrocarbons emitted from cigarette smoke"
Keywords:
Notes:"PubMed-not-MEDLINELiu, Xinyu Pawliszyn, Janusz eng Germany 2007/02/13 Anal Bioanal Chem. 2007 Apr; 387(7):2517-25. doi: 10.1007/s00216-007-1120-7. Epub 2007 Feb 10"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024