Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPosition 13 analogs of the tridecapeptide mating pheromone from Saccharomyces cerevisiae: design of an iodinatable ligand for receptor binding    Next Abstract"Volatile composition of bilberry wines fermented with non-Saccharomyces and Saccharomyces yeasts in pure, sequential and simultaneous inoculations" »

J Chromatogr B Biomed Sci Appl


Title:Optimized determination of trace jet fuel volatile organic compounds in human blood using in-field liquid-liquid extraction with subsequent laboratory gas chromatographic-mass spectrometric analysis and on-column large-volume injection
Author(s):Liu S; Pleil JD;
Address:"ManTech Environmental Technology, Inc., Research Triangle Park, NC 27709, USA"
Journal Title:J Chromatogr B Biomed Sci Appl
Year:2001
Volume:752
Issue:1
Page Number:159 - 171
DOI: 10.1016/s0378-4347(00)00537-5
ISSN/ISBN:1387-2273 (Print) 1387-2273 (Linking)
Abstract:"A practical and sensitive method to assess volatile organic compounds (VOCs) from JP-8 jet fuel in human whole blood was developed by modifying previously established liquid-liquid extraction procedures, optimizing extraction times, solvent volume, specific sample processing techniques, and a new on-column large-volume injection method for GC-MS analysis. With the optimized methods, the extraction efficiency was improved by 4.3 to 20.1 times and the detection sensitivity increased up to 660 times over the standard method. Typical detection limits in the parts-per-trillion (ppt) level range were achieved for all monitored JP-8 constituents; this is sufficient for assessing human fuels exposures at trace environmental levels as well as occupational exposure levels. The sample extractions are performed in the field and only solvent extracts need to be shipped to the laboratory. The method is implemented with standard biological laboratory equipment and a modest bench-top GC-MS system"
Keywords:Gas Chromatography-Mass Spectrometry/*methods Humans Hydrocarbons/*blood Reference Standards;
Notes:"MedlineLiu, S Pleil, J D eng Research Support, U.S. Gov't, Non-P.H.S. Netherlands 2001/03/20 J Chromatogr B Biomed Sci Appl. 2001 Mar 5; 752(1):159-71. doi: 10.1016/s0378-4347(00)00537-5"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 21-09-2024