Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPreliminary assessment of a model to predict mold contamination based on microbial volatile organic compound profiles    Next Abstract"Potential Hazards Not Communicated in Safety Data Sheets of Flavoring Formulations, Including Diacetyl and 2,3-Pentanedione" »

J Environ Monit


Title:Validation of evacuated canisters for sampling volatile organic compounds in healthcare settings
Author(s):LeBouf RF; Stefaniak AB; Virji MA;
Address:"National Institute for Occupational Safety and Health, 1095 Willowdale Road, Morgantown, WV 26505, USA. rlebouf@cdc.gov"
Journal Title:J Environ Monit
Year:2012
Volume:20120210
Issue:3
Page Number:977 - 983
DOI: 10.1039/c2em10896h
ISSN/ISBN:1464-0333 (Electronic) 1464-0325 (Linking)
Abstract:"Healthcare settings present a challenging environment for assessing low-level concentrations of specific volatile organic compounds (VOCs) in the presence of high background concentrations of alcohol from the use of hand sanitizers and surface disinfectants. The purposes of this laboratory-based project were to develop and validate a sampling and analysis methodology for quantifying low-level VOC concentrations as well as high-level alcohol concentrations found together in healthcare settings. Sampling was conducted using evacuated canisters lined with fused silica. Gas chromatography/mass spectrometry analysis was performed using preconcentration (for ppb levels) and loop injection (for ppm levels). For a select list of 14 VOCs, bias, precision, and accuracy of both the preconcentration and loop injection methods were evaluated, as was analyte stability in evacuated canisters over 30 days. Using the preconcentration (ppb-level) method, all validation criteria were met for 13 of the 14 target analytes-ethanol, acetone, methylene chloride, hexane, chloroform, benzene, methyl methacrylate, toluene, ethylbenzene, m,p-xylene, o-xylene, alpha-pinene, and limonene. Using the loop injection (ppm-level) method, all validation criteria were met for each analyte. At ppm levels, alpha-pinene and limonene remained stable over 21 days, while the rest of the analytes were stable for 30 days. All analytes remained stable over 30 days at ppb levels. This sampling and analysis approach is a viable (i.e., accurate and stable) methodology that will enable development of VOC profiles for mixed exposures experienced by healthcare workers"
Keywords:"Air Pollutants/*analysis Air Pollution, Indoor/*analysis/statistics & numerical data Environmental Monitoring/instrumentation/*methods Hospitals Occupational Exposure/analysis Volatile Organic Compounds/*analysis;"
Notes:"MedlineLeBouf, Ryan F Stefaniak, Aleksandr B Virji, M Abbas eng Validation Study England 2012/02/11 J Environ Monit. 2012 Mar; 14(3):977-83. doi: 10.1039/c2em10896h. Epub 2012 Feb 10"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-09-2024