Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractVisual cues of oviposition sites and spectral sensitivity of Cydia strobilella L    Next AbstractSample preparation for gas chromatographic determination of halogenated volatile organic compounds in environmental and biological samples »

J Chromatogr Sci


Title:Optimization of a novel procedure for determination of VOCs in water and human urine samples based on SBSE coupled with TD-GC-HRMS
Author(s):Jakubowska N; Henkelmann B; Schramm KW; Namiesnik J;
Address:"Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology (GUT), 80-952 Gdansk, Poland. nataliajakubowska26@wp.pl"
Journal Title:J Chromatogr Sci
Year:2009
Volume:47
Issue:8
Page Number:689 - 693
DOI: 10.1093/chromsci/47.8.689
ISSN/ISBN:0021-9665 (Print) 0021-9665 (Linking)
Abstract:"In this study, stir-bar sorptive extraction and thermal desorption followed by gas chromatography coupled with high resolution mass spectrometry was applied for determination of halo-organic compounds (bromodichloromethane, dibromochloromethane, bromoform, and tetrachloroethylene) in water and human urine samples. Time of extraction and stirring speed were optimized. The results show that the optimum extraction time is 30 min with 600 rpm of stirring speed with Twister of 20 mm in length and 1.0-mm film thickness of PDMS (126 microL). The calibration curves, limits of detection and quantification for all compounds were calculated. This procedure is characterized by very low limits of detection and quantitation: lower than 0.0017 microg/L and good repeatability for all four volatile compounds. This new analytical procedure was identified to be easy, reliable, sensitive, and requires only small amounts of sample. It can constitute a good alternative to well-known procedures based on application of head space and gas chromatography coupled with electron capture detection"
Keywords:"Chemical Fractionation/methods Chromatography, Gas/*methods Humans Hydrocarbons, Halogenated/*analysis/*urine Mass Spectrometry/*methods Reproducibility of Results Tetrachloroethylene/analysis/urine Trihalomethanes/analysis/urine Volatile Organic Compound;"
Notes:"MedlineJakubowska, Natalia Henkelmann, Bernhard Schramm, Karl-Werner Namiesnik, Jacek eng Research Support, Non-U.S. Gov't 2009/09/24 J Chromatogr Sci. 2009 Sep; 47(8):689-93. doi: 10.1093/chromsci/47.8.689"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-06-2024