Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"[Radioimmunoassay for the determination of boar pheromone delta 16-androsterone plasma levels in boars, sows and hogs as well as studies of the correlation between boar pheromone concentrations in plasma and adipose tissue]"    Next AbstractPlant genetic differences influence herbivore community structure: evidence from a hybrid willow system »

Analyst


Title:Preconcentration and detection of chlorinated organic compounds and benzene
Author(s):Hobson ST; Cemalovic S; Patel SV;
Address:"Seacoast Science, Inc., 2151 Las Palmas Drive, Suite C., Carlsbad, CA 92011, USA. sthobson@seacoastscience.com"
Journal Title:Analyst
Year:2012
Volume:20120123
Issue:5
Page Number:1284 - 1289
DOI: 10.1039/c2an16053f
ISSN/ISBN:1364-5528 (Electronic) 0003-2654 (Linking)
Abstract:"Remote and automated detection of organic compounds in subsurface aquifers is crucial to superfund monitoring and environmental remediation. Current monitoring techniques use expensive laboratory instruments and trained personnel. The use of a filled tubular preconcentrator combined with a chemicapacitive detector array presents an attractive option for the unattended monitoring of these compounds. Five preconcentrator materials were exposed to common target compounds of subsurface remediation projects (1,1,2-trichloroethane, trichloroethylene, t-1,2-dichloroethylene, benzene, and perchloroethylene). Rapid heating of the tube caused the collected, concentrated effluent to pass over the surface of a chemicapacitive detector array coated with four different sorbent polymers. A system containing a porous ladder polymer and the sensor array was subsequently used to sample the analytes injected onto sand in a laboratory test, simulating a subsurface environment. With extended collection times, effective detection limits of 5 +/- 3 ppbV for 1,1,2-trichloroethane and 145 +/- 60 ppbV for benzene were achieved. Effects of the preconcentrator material structure, the collection time, and sensor material on the system performance were observed. The resultant system presents a solution for remote, periodic monitoring of chlorinated organic compounds and other volatile organic compounds in a soil matrix"
Keywords:"Analytic Sample Preparation Methods/*methods Benzene/*analysis/chemistry Groundwater/chemistry Hydrocarbons, Chlorinated/*analysis/chemistry Soil/chemistry Soil Pollutants/*analysis/chemistry Water Pollutants/*analysis/chemistry;"
Notes:"MedlineHobson, Stephen T Cemalovic, Sabina Patel, Sanjay V eng 1R43ES016941-01/ES/NIEHS NIH HHS/ Research Support, N.I.H., Extramural England 2012/01/24 Analyst. 2012 Mar 7; 137(5):1284-9. doi: 10.1039/c2an16053f. Epub 2012 Jan 23"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024