Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractPolar volatile organic compounds (VOC) of natural origin as precursors of ozone    Next Abstract"Relaxed eddy accumulation, a new technique for measuring emission and deposition fluxes of volatile organic compounds by capillary gas chromatography and mass spectrometry" »

J Chromatogr A


Title:Simple laboratory-made system for the determination of C2-C7 hydrocarbons relevant to photochemical smog pollution
Author(s):Ciccioli P; Brancaleoni E; Mabilia R; Cecinato A;
Address:"Istituto sull'Inquinamento Atmosferico-C.N.R., Monterotondo Scalo RM, Italy"
Journal Title:J Chromatogr A
Year:1997
Volume:777
Issue:2
Page Number:267 - 274
DOI: 10.1016/s0021-9673(97)00380-4
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"A simple gas chromatographic system suitable for determining volatile organic compounds from C2 to C7 in air is described. It consists of a capillary cold trap filled with graphitic carbon, a thermodesorbing device, a capillary gas chromatograph equipped with an alumina column and a flame ionization detector. Dry, as well as humid, air samples can be analysed with our system. Up to 2-1 samples of air can be enriched on our trapping device by using Nafion membranes for removing water. Direct analysis of air samples is possible by enriching 250 ml on the carbon trap. The recovery, sensitivity and linearity of our system have been checked with standard mixtures and real samples. The performances have been compared with those afforded by a commercially available instrument exploiting a different enrichment procedure. The results obtained show that our analyser can be successfully applied to determinations of C2 to C7 hydrocarbons present in air samples at levels of 0.01 ppb (v/v)"
Keywords:"Air Pollutants/*analysis Chromatography, Gas/instrumentation/*methods Hydrocarbons/*analysis/chemistry Smog/*analysis Volatilization;"
Notes:"MedlineCiccioli, P Brancaleoni, E Mabilia, R Cecinato, A eng Research Support, Non-U.S. Gov't Netherlands 1997/08/15 J Chromatogr A. 1997 Aug 15; 777(2):267-74. doi: 10.1016/s0021-9673(97)00380-4"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 26-12-2024