Anal Chim Acta
Title: | Comparison of headspace solid-phase microextraction high capacity fiber coatings based on dual mass spectrometric and broadband vacuum ultraviolet absorption detection for untargeted analysis of beer volatiles using gas chromatography |
|
Author(s): | Zanella D; Anderson HE; Selby T; Magnuson RH; Liden T; Schug KA; |
|
Address: | "University of Liege, Molecular System, Organic & Biological Analytical Chemistry Group, 11 Allee Du Six Aout, 4000, Liege, Belgium. Department of Chemistry and Biochemistry, The University of Texas at Arlington, 700 Planetarium Place, Arlington, TX, 76019, USA. Department of Chemistry and Biochemistry, The University of Texas at Arlington, 700 Planetarium Place, Arlington, TX, 76019, USA. Electronic address: tiffany.liden@uta.edu. Department of Chemistry and Biochemistry, The University of Texas at Arlington, 700 Planetarium Place, Arlington, TX, 76019, USA; Affiliate of Collaborative Laboratories for Environmental Analysis and Remediation, The University of Texas at Arlington, Arlington, TX, 76019, USA. Electronic address: kschug@uta.edu" |
|
Journal Title: | Anal Chim Acta |
Year: | 2021 |
Volume: | 20201019 |
Issue: | |
Page Number: | 91 - 99 |
DOI: | 10.1016/j.aca.2020.10.026 |
|
ISSN/ISBN: | 1873-4324 (Electronic) 0003-2670 (Linking) |
|
Abstract: | "Despite the same basic ingredients used in brewing, there is a significant variation in beer styles. With the rapid increase in craft brewing, beer styles have become even more numerous and complex in the recent past. A GC-MS/VUV (post-column split for dual detection) instrument with headspace high capacity SPME was used to investigate 21 different beers which represent three beer styles - India pale ales, blondes, and hefeweizens. Since results from untargeted studies can be affected by the sorbent material used, the extraction performances of three high capacity SPME fibers, i.e., polydimethylsiloxane, polydimethylsiloxane/carbon wide range, and polydimethylsiloxane/carbon wide range/divinylbenzene, were evaluated. Good reproducibility (<10% RSD) was obtained for each high capacity fiber using both detectors. The tandem MS/VUV detection coupled with GC separation proved to be particularly valuable for compound identification, especially for isomers and compounds with similar structures. The evaluation of VUV detection for untargeted analysis led to similar performances as MS detection. Both the VUV and the MS were able to effectively differentiate between beer styles using principal component analysis. In addition, the use of 3 different statistical approaches, one-way ANOVA (p-value < 0.05), partial least square discriminant analysis, and random forest, universally identified 12 of the components most influential in distinguishing the three beer styles (e.g., beta-myrcene, linalool, isopentyl acetate, 2,4-di-tert-butylphenol). This is the first reported evaluation of VUV detection and the first comparison of simultaneous VUV and MS detection for untargeted classification of complex mixtures using GC" |
|
Keywords: | *Beer/analysis Gas Chromatography-Mass Spectrometry Reproducibility of Results *Solid Phase Microextraction Vacuum Absorption spectroscopy Beer volatiles Beverage analysis Multivariate classification SPME Arrow; |
|
Notes: | "MedlineZanella, Delphine Anderson, Hailee E Selby, Talena Magnuson, Robert H 2nd Liden, Tiffany Schug, Kevin A eng Netherlands 2020/11/30 Anal Chim Acta. 2021 Jan 2; 1141:91-99. doi: 10.1016/j.aca.2020.10.026. Epub 2020 Oct 19" |
|
|
|
|
|
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.