Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractMicrobial compositions and metabolic interactions in one- and two-phase partitioning airlift bioreactors treating a complex VOC mixture    Next Abstracto-Xylene removal using one- and two-phase partitioning biotrickling filters: steady/transient-state performance and microbial community »

Chemosphere


Title:Assessment of the health risks and odor concentration of volatile compounds from a municipal solid waste landfill in China
Author(s):Wu C; Liu J; Liu S; Li W; Yan L; Shu M; Zhao P; Zhou P; Cao W;
Address:"School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing, 100083, China. School of Chemistry and Biological Engineering, University of Science and Technology Beijing, Beijing, 100083, China. Electronic address: liujm@ustb.edu.cn. China Building Material Test & Certification Group Co., Ltd, Beijing, 100024, China. School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing, 100083, China. Key Laboratory of Occupational Health and Safety, Beijing Municipal Institute of Labor Protection, Beijing, 100054, China. BESG Environmental Engineering Co., Ltd, Beijing, 100101, China"
Journal Title:Chemosphere
Year:2018
Volume:20180313
Issue:
Page Number:1 - 8
DOI: 10.1016/j.chemosphere.2018.03.068
ISSN/ISBN:1879-1298 (Electronic) 0045-6535 (Linking)
Abstract:"Municipal solid waste (MSW) landfills are a source of odorous and toxic compounds. In this work, we present an integrated assessment of the odor concentration and human health risks of volatile compounds to evaluate the environmental quality at a MSW landfill. Air samples were collected seasonally from six areas of the landfill with different functions. The total concentrations of the compounds ranged from 204.0 to 7426.7?ª+mug?ª+m(-3), and the concentrations in temporarily and permanently capped areas were 50.3 and 83.4% lower than those in the tipping area, respectively. The odor concentration was greatest at the leachate collection tank (1732-6254 ou(E) m(-3)) and tipping area (1573-4113 ou(E) m(-3)) and was mainly caused by hydrogen sulfide (57.9 and 49.1%, respectively). Moreover, the odor concentration was positively correlated with the temperature (r?ª+=?ª+0.500, p?ª+
Keywords:Air Pollutants/*analysis China Environmental Monitoring/*methods Humans Odorants/*analysis Risk Assessment Seasons Solid Waste/*analysis Volatile Organic Compounds/*analysis *Waste Disposal Facilities Health risk Hydrogen sulfide Landfill gas Municipal so;
Notes:"MedlineWu, Chuandong Liu, Jiemin Liu, Shihua Li, Wenhui Yan, Luchun Shu, Mushui Zhao, Peng Zhou, Peng Cao, Wenbin eng England 2018/03/20 Chemosphere. 2018 Jul; 202:1-8. doi: 10.1016/j.chemosphere.2018.03.068. Epub 2018 Mar 13"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024