Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractInvestigations into the effect on rats of volatile organic compounds released from the set of building and finishing materials    Next Abstract[Application of mathematical models for determination of volatile organic compounds emission from flooring adhesives] »

Bull Inst Marit Trop Med Gdynia


Title:Emission of volatile organic compounds (VOCs) from PVC floor coverings
Author(s):Wiglusz R; Igielska B; Sitko E; Nikel G; Jarnuszkiewicz I;
Address:"Department of Toxicology, Institute of Maritime and Tropical Medicine, Gdynia, Poland"
Journal Title:Bull Inst Marit Trop Med Gdynia
Year:1998
Volume:49
Issue:1-Apr
Page Number:101 - 107
DOI:
ISSN/ISBN:0324-8542 (Print) 0324-8542 (Linking)
Abstract:"In this study 29 PVC floor coverings were tested for emission of vinyl chloride (VC) and other volatile organic compounds (VOCs). A study on the effect of higher temperature on emission of VOCs from newly manufactured PVC flooring was also carried out. The study was conducted in climatic chamber, according to Polish Standard PN-89/Z-04021. GC method was used for analyzing of the compounds emitted. VC was not emitted from any of the floorings tested. Other VOCs were emitted in different concentrations. The influence of temperature on emission was conducted at temperatures of 23 degrees C and 35 degrees C from 2 hrs up to 180 days after introduction of materials in the chamber. The increase of temperature caused increase of total volatile organic compounds (TVOC) emission during 24 hrs of experiment. Then the emission was comparable for both temperatures. After 9 days emission of identified and unidentified compounds (TVOC) showed a rapid decay and stayed on very low level during a few months. The study conducted showed that PVC floorings after 10 days of installation in the room should not be source of indoor air contamination"
Keywords:"Air Pollution, Indoor/*analysis *Floors and Floorcoverings Organic Chemicals/*analysis Poland Polyvinyl Chloride/*chemistry Temperature Vinyl Chloride/*analysis Volatilization;"
Notes:"MedlineWiglusz, R Igielska, B Sitko, E Nikel, G Jarnuszkiewicz, I eng Poland 1999/08/04 Bull Inst Marit Trop Med Gdynia. 1998; 49(1-4):101-7"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 28-12-2024