Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDifferent influences of beta-glucosidases on volatile compounds and anthocyanins of Cabernet Gernischt and possible reason    Next AbstractCoupling of comprehensive two-dimensional gas chromatography with quadrupole mass spectrometry: application to the identification of atmospheric volatile organic compounds »

Rapid Commun Mass Spectrom


Title:A high-efficiency real-time digital signal averager for time-of-flight mass spectrometry
Author(s):Wang Y; Xu H; Li Q; Li N; Huang Z; Zhou Z; Liu H; Sun Z; Xu X; Yu H; Liu H; Li DD; Wang X; Dong X; Gao W;
Address:"School of Electronic Science and Engineering, National University of Defense Technology, Changsha, Hunan, China"
Journal Title:Rapid Commun Mass Spectrom
Year:2013
Volume:27
Issue:10
Page Number:1155 - 1167
DOI: 10.1002/rcm.6553
ISSN/ISBN:1097-0231 (Electronic) 0951-4198 (Linking)
Abstract:"RATIONALE: Analog-to-digital converter (ADC)-based acquisition systems are widely applied in time-of-flight mass spectrometers (TOFMS) due to their ability to record the signal intensity of all ions within the same pulse. However, the acquisition system raises the requirement for data throughput, along with increasing the conversion rate and resolution of the ADC. It is therefore of considerable interest to develop a high-performance real-time acquisition system, which can relieve the limitation of data throughput. METHODS: We present in this work a high-efficiency real-time digital signal averager, consisting of a signal conditioner, a data conversion module and a signal processing module. Two optimization strategies are implemented using field programmable gate arrays (FPGAs) to enhance the efficiency of the real-time processing. A pipeline procedure is used to reduce the time consumption of the accumulation strategy. To realize continuous data transfer, a high-efficiency transmission strategy is developed, based on a ping-pong procedure. RESULTS: The digital signal averager features good responsiveness, analog bandwidth and dynamic performance. The optimal effective number of bits reaches 6.7 bits. For a 32 micros record length, the averager can realize 100% efficiency with an extraction frequency below 31.23 kHz by modifying the number of accumulation steps. In unit time, the averager yields superior signal-to-noise ratio (SNR) compared with data accumulation in a computer. CONCLUSIONS: The digital signal averager is combined with a vacuum ultraviolet single-photon ionization time-of-flight mass spectrometer (VUV-SPI-TOFMS). The efficiency of the real-time processing is tested by analyzing the volatile organic compounds (VOCs) from ordinary printed materials. In these experiments, 22 kinds of compounds are detected, and the dynamic range exceeds 3 orders of magnitude"
Keywords:Mass Spectrometry/*instrumentation/*methods Time Factors Volatile Organic Compounds/analysis;
Notes:"MedlineWang, Yinan Xu, Hui Li, Qingjiang Li, Nan Huang, Zhengxu Zhou, Zhen Liu, Husheng Sun, Zhaolin Xu, Xin Yu, Hongqi Liu, Haijun Li, David D-U Wang, Xi Dong, Xiuzhen Gao, Wei eng Research Support, Non-U.S. Gov't England 2013/04/18 Rapid Commun Mass Spectrom. 2013 May 30; 27(10):1155-67. doi: 10.1002/rcm.6553"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 21-09-2024