« Previous AbstractIon mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study    Next AbstractDistance-dependent danger responses in bacteria »

J Breath Res


Title:Alveolar gradients in breath analysis. A pilot study with comparison of room air and inhaled air by simultaneous measurements using ion mobility spectrometry
Author(s):Westhoff M; Kessler M; Baumbach JI;
Address:"Department of Pneumology, Sleep and Respiratory Medicine, Hemer Lung Clinic, Theo-Funccius-Str. 1, 58675 Hemer, Germany. Witten/Herdecke University, Alfred-Herrhausen-Str. 50, 58448 Witten, Germany. University of Applied Sciences Munster, Hufferstrasse 27, 48149 Munster, Germany. B. Braun Melsungen AG, Branch Dortmund, Center of Competence Breath Analysis, Otto-Hahn-Str. 15, 44227 Dortmund, Germany. Technical University Dortmund, Faculty Bio- and Chemical Engineering, Emil-Figge-Str. 70, 44227 Dortmund, Germany"
Journal Title:J Breath Res
Year:2023
Volume:20230904
Issue:4
Page Number: -
DOI: 10.1088/1752-7163/acf338
ISSN/ISBN:1752-7163 (Electronic) 1752-7155 (Linking)
Abstract:"Analyzing exhaled breath samples, especially using a highly sensitive method such as MCC/IMS (multi-capillary column/ion mobility spectrometry), may also detect analytes that are derived from exogenous production. In this regard, there is a discussion about the optimal interpretation of exhaled breath, either by considering volatile organic compounds (VOCs) only in exhaled breath or by additionally considering the composition of room air and calculating the alveolar gradients. However, there are no data on whether the composition and concentration of VOCs in room air are identical to those in truly inhaled air directly before analyzing the exhaled breath. The current study aimed to determine whether the VOCs in room air, which are usually used for the calculation of alveolar gradients, are identical to the VOCs in truly inhaled air. For the measurement of inhaled air and room air, two IMS, each coupled with an MCC that provided a pre-separation of the VOCs, were used in parallel. One device was used for sampling room air and the other for sampling inhaled air. Each device was coupled with a newly invented system that cleaned room air and provided a clean carrier gas, whereas formerly synthetic air had to be used as a carrier gas. In this pilot study, a healthy volunteer underwent three subsequent runs of sampling of inhaled air and simultaneous sampling and analysis of room air. Three of the selected 11 peaks (P4-unknown, P5-1-Butanol, and P9-Furan, 2-methyl-) had significantly higher intensities during inspiration than in room air, and four peaks (P1-1-Propanamine, N-(phenylmethylene), P2-2-Nonanone, P3-Benzene, 1,2,4-trimethyl-, and P11-Acetyl valeryl) had higher intensities in room air. Furthermore, four peaks (P6-Benzaldehyde, P7-Pentane, 2-methyl-, P8-Acetone, and P10-2-Propanamine) showed inconsistent differences in peak intensities between inhaled air and room air. To the best of our knowledge, this is the first study to compare simultaneous sampling of room air and inhaled air using MCC/IMS. The simultaneous measurement of inhaled air and room air showed that using room air for the calculation of alveolar gradients in breath analysis resulted in different alveolar gradient values than those obtained by measuring truly inhaled air"
Keywords:Humans *Breath Tests Pilot Projects *Ion Mobility Spectrometry 1-Butanol Acetone exhaled breath analysis inhaled air ion mobility spectrometry multi-capillary column room air simultaneous sampling;
Notes:"MedlineWesthoff, M Kessler, M Baumbach, J I eng England 2023/08/24 J Breath Res. 2023 Sep 4; 17(4). doi: 10.1088/1752-7163/acf338"

 