Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractIdentification of genes in the bW/bE regulatory cascade in Ustilago maydis    Next AbstractEffect of nighttime temperature on tomato plant defensive chemistry »

J Chromatogr A


Title:Immobilized artificial membrane chromatography coupled with atmospheric pressure ionization mass spectrometry
Author(s):Braddy AC; Janaky T; Prokai L;
Address:"Center for Drug Discovery, College of Pharmacy, University of Florida, Gainesville 32610-0497, USA"
Journal Title:J Chromatogr A
Year:2002
Volume:966
Issue:1-Feb
Page Number:81 - 87
DOI: 10.1016/s0021-9673(02)00700-8
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"Liquid chromatographic separations on monolayers of cell membrane phospholipids covalently immobilized to silica particles at high molecular density is used for mimicking solute partitioning into biological membranes that generally correlates with membrane transport. This technique called immobilized artificial membrane chromatography usually employs ultraviolet (UV) detection where a single compound is analyzed in a chromatographic run limiting thereby its throughput for drug discovery applications. For coupling with atmospheric pressure ionization mass spectrometry, the phosphate-buffered saline mobile phase was replaced with one that used ammonium acetate as a volatile buffer. While atmospheric pressure chemical ionization accommodated a purely aqueous effluent, interfacing with electrospray ionization required effluent splitting and the addition of an organic modifier (5%, v/v, acetonitrile). Neuropeptide FF antagonists as early-phase drug candidates were used for the comparative evaluation of the methods. Whereas electrospray ionization produced essentially no fragment ions, several compounds involved in our study yielded low-abundance molecular ions with atmospheric pressure chemical ionization. The use of mass spectrometry yielded data that correlated well with those obtained by the method employing UV detection. Both atmospheric pressure ionization methods permitted the simultaneous determination of the k'(IAM), capacity factors and, therefore, an increased-throughput ranking of potential new leads emerged from the drug discovery process based on affinity to artificial membranes"
Keywords:"Atmospheric Pressure Chromatography, Liquid/*methods *Membranes, Artificial Oligopeptides/analysis Spectrometry, Mass, Electrospray Ionization/*methods;"
Notes:"MedlineBraddy, April C Janaky, Tamas Prokai, Laszlo eng DA10543/DA/NIDA NIH HHS/ MH59360/MH/NIMH NIH HHS/ Research Support, U.S. Gov't, P.H.S. Netherlands 2002/09/07 J Chromatogr A. 2002 Aug 9; 966(1-2):81-7. doi: 10.1016/s0021-9673(02)00700-8"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 06-07-2024