Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractFlux of the biogenic volatiles isoprene and dimethyl sulfide from an oligotrophic lake    Next AbstractCuticular lipids as trail pheromone in a social wasp »

J Occup Environ Hyg


Title:Characterization of emissions from a desktop 3D printer and indoor air measurements in office settings
Author(s):Steinle P;
Address:"a Suva, Bereich Analytik , Lucerne , Switzerland"
Journal Title:J Occup Environ Hyg
Year:2016
Volume:13
Issue:2
Page Number:121 - 132
DOI: 10.1080/15459624.2015.1091957
ISSN/ISBN:1545-9632 (Electronic) 1545-9624 (Linking)
Abstract:"Emissions from a desktop 3D printer based on fused deposition modeling (FDM) technology were measured in a test chamber and indoor air was monitored in office settings. Ultrafine aerosol (UFA) emissions were higher while printing a standard object with polylactic acid (PLA) than with acrylonitrile butadiene styrene (ABS) polymer (2.1 x 10(9) vs. 2.4 x 10(8) particles/min). Prolonged use of the printer led to higher emission rates (factor 2 with PLA and 4 with ABS, measured after seven months of occasional use). UFA consisted mainly of volatile droplets, and some small (100-300 nm diameter) iron containing and soot-like particles were found. Emissions of inhalable and respirable dust were below the limit of detection (LOD) when measured gravimetrically, and only slightly higher than background when measured with an aerosol spectrometer. Emissions of volatile organic compounds (VOC) were in the range of 10 microg/min. Styrene accounted for more than 50% of total VOC emitted when printing with ABS; for PLA, methyl methacrylate (MMA, 37% of TVOC) was detected as the predominant compound. Two polycyclic aromatic hydrocarbons (PAH), fluoranthene and pyrene, were observed in very low amounts. All other analyzed PAH, as well as inorganic gases and metal emissions except iron (Fe) and zinc (Zn), were below the LOD or did not differ from background without printing. A single 3D print (165 min) in a large, well-ventilated office did not significantly increase the UFA and VOC concentrations, whereas these were readily detectable in a small, unventilated room, with UFA concentrations increasing by 2,000 particles/cm(3) and MMA reaching a peak of 21 microg/m(3) and still being detectable in the room even 20 hr after printing"
Keywords:"Acrylic Resins Air Pollutants, Occupational/*analysis Air Pollution, Indoor/*analysis Butadienes Gases/analysis Lactic Acid Metals/analysis Methylmethacrylate/analysis Particulate Matter Polyesters Polymers Polystyrenes *Printing, Three-Dimensional Styren;"
Notes:"MedlineSteinle, Patrick eng Comparative Study Research Support, Non-U.S. Gov't England 2015/11/10 J Occup Environ Hyg. 2016; 13(2):121-32. doi: 10.1080/15459624.2015.1091957"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 21-09-2024