Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractDevelopment of fluorescent-labeled trapping reagents based on cysteine to detect soft and hard electrophilic reactive metabolites    Next AbstractAnalysis of Odor-Tracking Performance of Silk Moth Using a Sensory-Motor Intervention System »

Open Anal Chem J


Title:Counter-Current Chromatographic Separation of Nucleic Acid Constituents with a Polar Volatile Organic-Aqueous Two-Phase Solvent Systems with ELSD Detection
Author(s):Shibusawa Y; Morikawa G; Yanagida A; Ito Y;
Address:"Division of Pharmaceutical and Biomedical Analysis, School of Pharmacy, Tokyo University of Pharmacy and Life Science, 1432-1 Horinouchi, Hachioji, Tokyo 192-0392, Japan. Bioseparation Technology, Biochemistry and Biophysics Center, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA"
Journal Title:Open Anal Chem J
Year:2012
Volume:6
Issue:
Page Number:9 - 14
DOI: 10.2174/1874065001206010009
ISSN/ISBN:1874-0650 (Print) 1874-0650 (Electronic) 1874-0650 (Linking)
Abstract:"Highly hydrophilic volatile organic/aqueous two-phase solvent systems containing an organic salt such as, acetonitrile/800 mM and 1200 mM ammonium acetate (1 : 1, v/v) were efficiently utilized for high-speed counter-current chromatography (HSCCC) to separate hydrophilic compounds. The retention of the upper and the lower stationary phases in the column of the cross-axis coil planet centrifuge (CCC instrument) was studied by changing the flow-rate of the mobile phase (1.0-3.0 ml/min). Using the acetonitrile/800 mM ammonium acetate two-phase solvent system, the stationary phase was retained at 46.3% relative to the total column capacity of 65 ml by the reversed-phase elution mode at a flow-rate of 1.0 ml/min. The best retention of the stationary upper phase of 51.5% was obtained by the solvent system of the acetonitrile/1200 mM ammonium acetate at the above flow-rate. With the acetonitrile/800 mM ammonium acetate system the base line separation of adenine and adenosine monophosphate (AMP) detected by evaporative light scattering detector (ELSD) and UV was achieved with lower phase mobile at a flow-rate of 1.0 ml/min within 70 min"
Keywords:Amp Elsd Hsccc hydrophilic compounds;
Notes:"PubMed-not-MEDLINEShibusawa, Yoichi Morikawa, Go Yanagida, Akio Ito, Yoichiro eng Z99 HL999999/Intramural NIH HHS/ Netherlands 2012/01/01 Open Anal Chem J. 2012; 6:9-14. doi: 10.2174/1874065001206010009"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024