Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractModel for predicting comprehensive two-dimensional gas chromatography retention times    Next AbstractInterspecific attractivity of female sex pheromone components ofPeriplaneta americana »

J Breath Res


Title:In vitro SIFT-MS validation of a breath fractionating device using a model VOC and ventilation system
Author(s):Seeley MJ; Hu WP; Scotter JM; Storer MK; Shaw GM;
Address:"University of Otago, Christchurch, New Zealand"
Journal Title:J Breath Res
Year:2009
Volume:20090108
Issue:1
Page Number:16001 -
DOI: 10.1088/1752-7155/3/1/016001
ISSN/ISBN:1752-7155 (Print) 1752-7155 (Linking)
Abstract:"The measurement of volatile organic compounds in exhaled breath is becoming recognized as a method of disease diagnosis and therapeutic monitoring. The aim of this study was to validate the collection of breath from intubated patients in the intensive care setting. This was done by assembling a system of ventilators and humidification to emulate the human respiratory system. A known concentration of acetone was spiked into the system to simulate alveolar and dead-space 'breath'. Selected-ion flow tube mass spectrometry (SIFT-MS) was used to directly measure gas at two separate points (headspace, distal circuit end) and from Tedlar bags collected using a remote breath fractionator. The mean acetone concentration for headspace, distal circuit end and Tedlar bag concentrations were calculated. The fractionator was effective in separating the early (dead space) and late phases of exhaled breath. Results from the late Tedlar bag samples collected by the remote breath fractionator showed a clear correlation with headspace and distal circuit end acetone concentrations. The collection for remote analysis of breath samples from immobile patients is made possible using the breath fractionator in conjunction with SIFT-MS analysis"
Keywords:
Notes:"PubMed-not-MEDLINESeeley, Matthew J Hu, Wan-Ping Scotter, Jennifer M Storer, Malina K Shaw, Geoffrey M eng England 2009/03/01 J Breath Res. 2009 Mar; 3(1):016001. doi: 10.1088/1752-7155/3/1/016001. Epub 2009 Jan 8"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024