Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractFlame retardants in the indoor environment -- Part II: release of VOCs (triethylphosphate and halogenated degradation products) from polyurethane    Next AbstractCritical evaluation of approaches in setting indoor air quality guidelines and reference values »

Chemosphere


Title:Comparison of analytical techniques for the determination of aldehydes in test chambers
Author(s):Salthammer T; Mentese S;
Address:"Fraunhofer Wilhelm-Klauditz-Institute (WKI), Material Analysis and Indoor Chemistry, Bienroder Weg 54 E, 38108 Braunschweig, Germany. tunga.salthammer@wki.fraunhofer.de"
Journal Title:Chemosphere
Year:2008
Volume:20080822
Issue:8
Page Number:1351 - 1356
DOI: 10.1016/j.chemosphere.2008.06.054
ISSN/ISBN:1879-1298 (Electronic) 0045-6535 (Linking)
Abstract:"The level of carbonyl compounds in indoor air is crucial due to possible health effects and the high prevalence of their potential sources. Therefore, selecting a convenient and rapid analytical technique for the reliable detection of carbonyl compound concentrations is important. The acetyl acetone (acac) method is a widely used standard procedure for detecting gaseous formaldehyde. For measuring formaldehyde along with other carbonyl compounds, the DNPH-method is commonly applied. The recommended procedure for measuring volatile organic compounds (VOCs) is sampling on Tenax TA, followed by thermal desorption and GC/MS analysis. In this study, different analytical techniques for the quantification of formaldehyde, pentanal, and hexanal are critically compared. It was found that the acac- and DNPH-method are in very good agreement for formaldehyde. In contrast, the DNPH-method significantly underestimates indoor air concentrations of the higher aldehydes in comparison to sampling on Tenax TA, although both methods are strongly correlated. The reported results are part of the EURIMA-WKI study on levels of indoor air pollutants resulting from construction, building materials and interior decoration"
Keywords:"Air Pollution, Indoor/analysis Aldehydes/*analysis Calcium Compounds/chemistry Construction Materials/*analysis Formaldehyde/analysis Silicates/chemistry;"
Notes:"MedlineSalthammer, Tunga Mentese, Sibel eng Comparative Study Research Support, Non-U.S. Gov't England 2008/08/30 Chemosphere. 2008 Nov; 73(8):1351-6. doi: 10.1016/j.chemosphere.2008.06.054. Epub 2008 Aug 22"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024