Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAssessment of changes in microbial community structure during operation of an ammonia biofilter with molecular tools    Next Abstract"Enzymatic resolution and odor description of both enantiomers of lavandulol, a fragrance of lavender oil" »

J Chromatogr A


Title:Development of a static headspace gas chromatographic/mass spectrometric method to analyze the level of volatile contaminants biodegradation
Author(s):Sakata SK; Taniguchi S; Rodrigues DF; Urano ME; Wandermuren MN; Pellizari VH; Comasseto JV;
Address:"Instituto de Quimica, Universidade de Sao Paulo, Av Prof. Lineu Prestes 748, 05508-900 Sao Paulo, Brazil. sosakata@iq.usp.br"
Journal Title:J Chromatogr A
Year:2004
Volume:1048
Issue:1
Page Number:67 - 71
DOI: 10.1016/j.chroma.2004.07.021
ISSN/ISBN:0021-9673 (Print) 0021-9673 (Linking)
Abstract:"Volatile compound biodegradation analysis usually requires the time-consuming step of extraction of the analytes from the matrix using organic solvents or costly radioactive-compounds. Thus, it is desirable to have a simple and fast technique to generate a good evaluation of bacterial biodegradation. The goal of this research was to develop a methodology on the basis of static headspace-gas chromatography/mass spectrometry (HS-GC/MS) to evaluate the level of volatile contaminant biodegradation. The effects of the following parameters were studied: temperature and time of equilibration. The biodegradation experiments were carried out with bacteria inoculation in mineral media in presence of volatile hydrocarbon compounds (toluene, p-xylene, nonane and naphthalene). Autoclaved inoculates were used as control and reference sample. The optimal headspace conditions were observed when the vials were heated at 80 degrees C for 20 min, the syringe at 81 degrees C and an injection volume of 0.4 mL was used. This methodology has the advantage of being relative free from matrix effects"
Keywords:"Biodegradation, Environmental Gas Chromatography-Mass Spectrometry/*methods Volatilization;"
Notes:"MedlineSakata, Solange K Taniguchi, Satie Rodrigues, Debora F Urano, Miriam E Wandermuren, Marcio N Pellizari, Vivian H Comasseto, Joao V eng Research Support, Non-U.S. Gov't Netherlands 2004/09/30 J Chromatogr A. 2004 Sep 3; 1048(1):67-71. doi: 10.1016/j.chroma.2004.07.021"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 21-09-2024