Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAbiotic and Biotic Damage of Microalgae Generate Different Volatile Organic Compounds (VOCs) for Early Diagnosis of Algal Cultures for Biofuel Production    Next AbstractAn Idiographic Investigation of Diabetic Alert Dogs' Ability to Learn From a Small Sample of Breath Samples From People With Type 1 Diabetes »

Behav Processes


Title:Assessing individual performance and maintaining breath sample integrity in biomedical detection dogs
Author(s):Reeve C; Wentzell P; Wielens B; Jones C; Stehouwer K; Gadbois S;
Address:"Canid Behaviour Research Lab, Department of Psychology and Neuroscience, Dalhousie University, Halifax, N.S., B3H 4R2, Canada,. Electronic address: reevecat@dal.ca. Department of Chemistry, Dalhousie University, Halifax, N.S., B3H 4R2, Canada. 908 Devices Inc., Boston, MA, USA. Atlantic Veterinary College, U.P.E.I., Charlottetown, P.E.I.,C1A 4P3 Canada. Maastricht University, Netherlands. Canid Behaviour Research Lab, Department of Psychology and Neuroscience, Dalhousie University, Halifax, N.S., B3H 4R2, Canada"
Journal Title:Behav Processes
Year:2018
Volume:20170818
Issue:
Page Number:8 - 18
DOI: 10.1016/j.beproc.2017.08.008
ISSN/ISBN:1872-8308 (Electronic) 0376-6357 (Linking)
Abstract:"In empirical tests of biomedical detection dogs, exhaled breath samples are often used because breath contains volatile organic compounds that can signal metabolic states, infection, or disease. However, in studies that present dogs with breath samples, results show a notable degree of variability both between and within studies. Differing protocols for the collection and storage of exhaled breath samples may contribute to this observed variability. The goal of the current study was therefore to test whether there was a difference in the detectability of breath samples collected using silicone-coated versus uncoated cotton balls. This was tested in two experiments. In the first experiment, breath samples were prepared using both silicone-coated and uncoated cotton balls, which were then left exposed to the surrounding air. Four dogs' detection of the samples was tested using a cued, three alternative forced choice (3AFC) procedure at regular intervals up to two hours after the samples were prepared. The results of Experiment 1 showed that the dogs' performance was above chance and there was no significant difference in the dogs' detection of the breath samples across conditions. In the second experiment, a series of breath samples were prepared and stored for one, two, three, and four week periods. The same four dogs' ability to detect the breath samples was tested each week using the same cued 3AFC procedure. The results of Experiment 2 showed that when silicone-coated cotton balls were used, all four dogs could detect the breath samples at above chance levels after the samples were stored for three weeks, and two dogs could detect the samples that were stored for four weeks. When the dogs were tested on their ability to detect the breath samples prepared using uncoated cotton, two dogs' performance fell to below chance levels at one week of storage time, while the other two dogs could detect the breath samples at above chance levels after the samples were stored for four weeks. Taken together, the results of the two experiments illustrate that silicone-coated cotton balls do not improve detectability of breath samples within two hours, but can greatly improve the detectability of breath samples stored over longer periods of time. Since the use of silicone-coated cotton balls only improved the detectability of the breath samples for two of the four dogs, these results highlight the importance of examining individual differences in dogs' performance. Furthermore, we argue that, given the inherent differences in olfactory ability across dogs, widespread use of silicone-coated cotton balls for the collection of breath samples would increase the pool of testable dogs for biomedical detection studies and would decrease the degree of variability both within and between studies"
Keywords:Animals Breath Tests/*methods Cues *Diagnostic Techniques and Procedures Dogs Female Humans Individuality Male Psychomotor Performance/*physiology Smell/physiology Specimen Handling Volatile Organic Compounds Breath samples Breath volatiles Canine olfacti;
Notes:"MedlineReeve, Catherine Wentzell, Peter Wielens, Bjorn Jones, Cortney Stehouwer, Kim Gadbois, Simon eng Netherlands 2017/08/23 Behav Processes. 2018 Oct; 155:8-18. doi: 10.1016/j.beproc.2017.08.008. Epub 2017 Aug 18"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 10-11-2024