Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous Abstract"Field Efficacy of Verticillium lecanii, Sex Pheromone, and Pheromone Analogs as Potential Management Agents for Soybean Cyst Nematode"    Next Abstract"Herbivore perception decreases photosynthetic carbon assimilation and reduces stomatal conductance by engaging 12-oxo-phytodienoic acid, mitogen-activated protein kinase 4 and cytokinin perception" »

Chemosphere


Title:Estimating octanol-air partition coefficients with octanol-water partition coefficients and Henry's law constants
Author(s):Meylan WM; Howard PH;
Address:"Syracuse Research Corporation, Environmental Science Center, 301 Plainfield Road--Suite 350, Syracuse, NY 13202, USA"
Journal Title:Chemosphere
Year:2005
Volume:61
Issue:5
Page Number:640 - 644
DOI: 10.1016/j.chemosphere.2005.03.029
ISSN/ISBN:0045-6535 (Print) 0045-6535 (Linking)
Abstract:"The octanol-air partition coefficient (K(OA)) is useful for predicting the partitioning behavior of organic compounds between air and environmental matrices such as soil, vegetation, and aerosol particles. At present, experimentally determined K(OA) values are available for only several hundred compounds. Therefore, the ability to estimate K(OA) is necessary for screening level evaluation of most chemicals. Although it is possible to estimate K(OA) from the octanol-water partition coefficient (K(OW)) and Henry's law constant (HLC), various concerns have been raised in regard to the usability of this estimation methodology. This work examines the accuracy and usability of K(OW) and HLC in application to a comprehensive database set of K(OA) values for screening level environmental assessment. Results indicate that K(OW) and HLC can be used to accurately predict K(OA) even when estimated K(OW) and HLC values are used. For an experimental dataset of 310log K(OA) values for different compounds, the K(OW)-HLC method was statistically accurate as follows: correlation coefficient (r2): 0.972, standard deviation: 0.526, absolute mean error: 0.358 using predominantly experimental K(OW) and HLC values. When K(OW) and HLC values were estimated (using the KOWWIN and HENRYWIN programs), the statistical accuracy was: correlation coefficient (r2): 0.957, standard deviation: 0.668, absolute mean error: 0.479"
Keywords:"1-Octanol/*chemistry *Air Algorithms Environmental Monitoring *Environmental Pollutants *Models, Chemical Solubility Volatilization Water/*chemistry;"
Notes:"MedlineMeylan, William M Howard, Philip H eng England 2005/05/24 Chemosphere. 2005 Nov; 61(5):640-4. doi: 10.1016/j.chemosphere.2005.03.029"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 27-12-2024